Rated data
Inverter power supply 400 V, self-ventilated motors
Motor
MCA 10I40-
MCA 13I41-
MCA 14L41-
MCA 14L20-
MCA 17N23-
MCA 17N41-
Degree of protection
IPxx
IPxx
IPxx
IPxx
IPxx
IPxx
Standstill torque
M
0
Nm
2.30
4.60
8.00
8.00
12.8
12.8
Rated torque
M
rated
Nm
2.00
4.00
5.40
6.70
10.8
9.50
Max. torque
M
max
Nm
10.0
32.0
60.0
60.0
100
100
Rated speed
n
rated
rpm
3950
4050
4100
2000
2300
4110
Max. speed
n
max
rpm
8000
8000
8000
8000
8000
8000
Rated power
P
rated
kW
0.8
1.7
2.3
1.4
2.6
4.1
Standstill current
I
0
A
2.55
4.60
7.70
3.85
6.00
12.0
Rated current
I
rated
A
2.40
4.40
5.80
3.30
5.50
10.2
Max. current
I
max
A
9.60
17.6
23.2
13.2
22.0
40.8
Rated voltage
V
rated
V
390
390
390
390
390
350
Rated frequency
f
rated
Hz
140
140
140
70
80
140
Moment of inertia
J
kgcm²
2.40
8.30
19.2
19.2
36.0
36.0
Efficiency
η
0.700
0.750
0.780
0.840
0.860
0.830
Stator terminal resistance
R
UV 20
°C
Ω
9.4
3.4
1.5
6
3.04
0.76
Stator terminal resistance
R
UV 150
°C
Ω
14.166
5.124
2.261
9.042
4.581
1.145
Mutual inductance
L
H
mH
169.15
92.64
65.8
268.7
176.4
43.4
Stator leakage inductance
L
1σ
mH
9.8
5.408
2.493
9.971
6.162
1.536
Rotor leakage inductance
L
2σ
mH
10
4.896
2.503
10.016
6.836
1.703
Stator resistance
R
1, 20
Ω
4.7
1.7
0.75
3
1.52
0.38
Rotor resistance
R
2‘, 20
Ω
5.2
1.4
0.781
3.13
1.37
0.342
Weight
m
kg
6.40
10.4
15.1
15.1
22.9
22.9
Technical data
Rated data
Inverter power supply 400 V, self-ventilated motors