Safety instructions
Residual hazards
l
38
EDKRBS470R DE/EN/FR 10.0
(
Stop!
Possible overheating of the brake resistor during operation
Inadequate heat dissipation during operation can cause the brake
resistor to overheat.
Possible consequences:
ƒ
The brake resistor is destroyed.
ƒ
The drive is not braked but coasts to a standstill.
Protective measures:
ƒ
Always connect the thermal contact of the brake resistor.
ƒ
Integrate the thermal contact into the overall equipment
monitoring apparatus in such a way that the supply of power to
the standard device is switched off if the brake resistor overheats
(e.g. switch−off by means of mains contactor control).
Содержание L-force ERBS R Series
Страница 30: ...Wartung 7 l 30 EDKRBS470R DE EN FR 10 0...
Страница 58: ...Maintenance 7 l 58 EDKRBS470R DE EN FR 10 0...
Страница 86: ......