Blower
The motor is optionally available with a blower for operation with the rated torque and low
motor speeds or a higher switching frequency.
The blower cools the motor independent of the motor speed.
If a blower is used, the torque does not have to be reduced if operated below 20 Hz.
A higher powered motor with simultaneous derating can be used in many cases
instead of a blower.
Torque reduction at low motor frequencies
Standard version
Motor series
m540-P
Size
090
100
112
Number of phases
1
3
3
1
3
3
1
3
3
Wiring
Delta
Delta
Star
Delta
Delta
Star
Delta
Delta
Star
Rated voltage
V
rated
V
230
230
400
230
230
400
230
230
400
Rated power
P
rated
kW
0.065
0.091
0.091
0.075
0.091
0.091
0.094
0.1
0.1
Rated current
I
rated
A
0.29
0.38
0.22
0.3
0.37
0.22
0.37
0.35
0.2
Motor series
m540-P
Size
132
160
180
Number of phases
1
3
3
1
3
3
1
3
3
Wiring
Delta
Delta
Star
Delta
Delta
Star
Delta
Delta
Star
Rated voltage
V
rated
V
230
230
400
230
230
400
230
230
400
Rated power
P
rated
kW
0.15
0.15
0.15
0.25
0.36
0.36
0.23
0.22
0.22
Rated current
I
rated
A
0.57
0.58
0.33
0.97
0.93
0.56
0.93
0.71
0.4
Motor series
m540-P
Size
200
225
250
Number of phases
1
3
3
3
3
3
3
Wiring
Delta
Delta
Star
Delta
Star
Delta
Star
Rated voltage
V
rated
V
230
230
400
230
400
230
400
Rated power
P
rated
kW
0.23
0.22
0.22
0.45
0.45
0.45
0.45
Rated current
I
rated
A
0.93
0.85
0.51
2
1.15
2
1.15
Product extensions
Blower
Standard version
96