14.3
Configure digital outputs
14.3.1
Digital output 1
Settings for digital output 1.
Details
The digital output 1 is controlled with the trigger selected in .
The following settings are possible for the digital output:
•
Inversion
①
•
Manual I/O control
②
0x2634:002
Trigger
0
1
0
1
1
DO1
0x4016:005
0x60FE
0x2635:002
0x263C:001
X3
0x263C:002
Diagnostic parameters:
•
Display of the logic state of the trigger signal:
•
Display of the logic state of the digital output:
Inversion
The trigger signal of the digital output can be internally inverted logically.
Manual I/O control
The digital output can be overridden manually. After the function is activated, the actual val-
ues are "frozen". Afterwards, each digital output can be overwritten manually.
Setting:
•
•
Entering the manual value:
Parameter
Address
Name / setting range / [default setting]
Info
0x2635:002
Inversion of digital outputs: Digital output 1
Inversion of digital output 1
0 Not inverted
1 Inverted
0x4016:005
Digital output 1: Terminal state
•
Read only
Display of the logic state of output terminal X3/DO1.
0 FALSE
1 TRUE
0x263C:001
Digital outputs internal control: Activation
0 Aus
1 Ein
0x263C:002
Digital outputs internal control: DO1 internal control
0 Aus
1 Ein
I/O extensions and control connections
Configure digital outputs
Digital output 1
311
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......