12.4.1
Monitoring the pole position identification
If an error occurs during the pole position identification or if the pulse inhibit gets active (e.g.
due to a short-time undervoltage), the process is stopped with disabling the inverter without
the settings being changed.
If the motor was braked or blocked during the process, this will be detected at the end of the
measurement and no change will be made (exception: "pole position identification PLI (with-
out movement)").
The error response can be parameterised:
If an error occurs during the pole position identification,
•
the procedure is stopped without the settings being changed.
•
the response set in
is effected.
Parameter
Address
Name / setting range / [default setting]
Info
0x2C60
PPI monitoring: Reaction
Selection of the response triggered by the occurrence of an error during
the pole position identification (PLI).
Associated error codes:
•
65284 | 0xFF04 - RANLI_CIMES_1000_20880
•
65299 | 0xFF13 - RANLI_CIMES_1000_15967
0 No response
1 Fault > CiA402
2 Warning