12.2.4
Detection of changed settings of the feedback system
Bit 0 of status word 2 indicates whether the settings of the feedback system have been
changed since leaving the Not ready to start state. If a change has been made, bit 0 is set to
value "1".
During the transition to the Operation enabled state, bit 0 is reset to value "0".
In all device states, changes to the following parameters continue to be monitored.
Relevant parameters of other functions
Address
Designation
Default setting
Setting range
Load encoder/master encoder type
SinCos encoder [1]
Selection list
Hiperface load encoder/master encoder settings: Type
code manual input
0
0 ... 255
Hiperface load encoder/master encoder settings: No.
of periods manual input
1
1 ... 65535
Hiperface load encoder/master encoder settings:
Serial number
- (Read only)
Load encoder/master encoder settings (encoder):
Increments/revolution
1024
1 ... 131072
Position encoder resolution : Encoder increments
16 bit [65536]
Selection list
Position encoder resolution : Motor revolutions
1
1 ... 1
12.2.5
Diagnostics
Parameter
Address
Name / setting range / [default setting]
Info
0x2C56
Number of the absolute ascertainable revolutions of
load encoder/master encoder
•
Read only
Is set by the firmware according to the available version:
•
0: no absolute value encoder (sin/cos encoder) or resolver with num-
ber of pole pairs > 1
•
1: Hiperface encoder SingleTurn or resolver with number of pole
pairs = 1
•
> 1: Hiperface encoder Multi Turn
0x2C5F
Parameter CRC of load encoder/master encoder
•
Read only
Display of the cyclic redundancy check (CRC) of selected encoder param-
eters to detect changes in the feedback settings.
0x2DDF:006
Axis information: Load encoder/master encoder
•
Read only
Display of the supported feedback system for the application.
Cannot be used as motor feedback.
0 Produktdefiniert
1 Kein Geber
2 Resolver
3 SinCos-Geber oder Hiperface-Absolutwert-
geber
0x60E4:001
Additional position actual value: Load encoder/master
encoder - actual position
•
Read only: x pos. unit
Display of the actual position of the secondary feedback system.
0x60E5:001
Additional velocity actual value: Load encoder/master
encoder - actual speed
•
Read only: rpm
Display of the actual velocity of the secondary feedback system.
Configuring the feedback system
Second feedback system for the techology application
Diagnostics
223
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......