The conversion ratio is freely adjustable via a virtual gearbox factor. The conversion ratio is
specified via the Stretch factor - numerator and Stretch factor - denominator parameters.
•
•
Stretch factor - denominator
If the gearbox factor is set to the ratio 2:1 for instance (Stretch factor - numerator = 2 and
Stretch factor - denominator = 1), the synchronism response will look like this:
0
100
200
300
Position
[u]
400
Fig. 50: Various synchronism representations
Parameter
Address
Name / setting range / [default setting]
Info
0x500A:031
Cycle length
0.0001 ... [360.0000] ... 214748.3647
•
Setting can only be changed if the inverter is inhibi-
ted.
The cycle length for an unlimited traversing range defines the position
where the measuring system is repeated (position return to 0).
0x500B:031
Cycle length
0.0001 ... [360.0000] ... 214748.3647
•
Setting can only be changed if the inverter is inhibi-
ted.
0x500C:031
Cycle length
0.0001 ... [360.0000] ... 214748.3647
•
Setting can only be changed if the inverter is inhibi-
ted.
The cycle length for an unlimited traversing range defines at which posi-
tion the measuring system is repeated (position return to 0).
0x5041:020
Stretch factor - numerator
-2147483648 ... [1] ... 2147483647
0x5041:021
Stretch factor - denominator
-2147483648 ... [1] ... 2147483647
Configuring the "Sync and Correction" TA
Position synchronism
122
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......