21
Commissioning
Operating instructions I510-Cabinet
Display code
Name
Possible settings/
value ranges
Keypad code
Information
P400.18
Setp: Preset B0
Digital input 4
[14]
Assignment of a trigger to the “Activate preset (bit 0)” function.Bit with the value 20 for the bit-coded selection and activation of a configured
setpoint (preset value).
Trigger = FALSE: Bit = “0”.
Trigger = TRUE: Bit = “1”.
P400.19
Setp: Preset B1
Digital input 5
[15]
Assignment of a trigger to the “Activate preset (bit 1)” function.Bit with the value 21 for the bit-coded selection and activation of a configured
setpoint (preset value).
Trigger = FALSE: Bit = “0”.
Trigger = TRUE: Bit = “1”.
P400.20
Setp: Preset B2
Not connected
[0]
Assignment of a trigger to the “Activate preset (bit 2)” function.Bit with the value 22 for the bit-coded selection and activation of a configured
setpoint (preset value).
Trigger = FALSE: Bit = “0”.
Trigger = TRUE: Bit = “1”.
P420.01
Relay function
Running
[50]
TRUE if inverter and start are enabled and output frequency > 0.2 Hz. Otherwise FALSE.
Ready for operation
[51]
TRUE if inverter is ready for operation (no error active, no STO active and DC-bus voltage ok). Otherwise FALSE.
Operation enabled
[52]
TRUE if inverter and start are enabled. Otherwise FALSE.
Stop active
[53]
TRUE if inverter is enabled and motor is not started and output frequency = 0.
Error active
[56]
TRUE if error is active. Otherwise FALSE.
Device warning active
[58]
TRUE if warning is active. Otherwise FALSE.
P420.02
DO1 function
Release brake
[115]
Assignment of a trigger to digital output 1.
Trigger = FALSE: X3/DO1 set to LOW level.
Trigger = TRUE: X3/DO1 set to HIGH level.
P430.01
AI1 input area
0 ... 10 VDC
[0]
Definition of the input range.
0 ... 5 VDC
[1]
2 ... 10 VDC
[2]
-10 ... +10 VDC
[3]
4 ... 20 mA
[4]
0 ... 20 mA
[5]
P430.02
AI1 freq @ min
- 1000.0 ... 0.0 ... 1000.0 Hz
Definition of the setting range for AI1.
• Direction of rotation according to sign.
• Standard setpoint source for operating mode is selected in
P201.01
.
P430.03
AI1 freq @ max
50.0 Hz * | 60.0 Hz *
Definition of the setting range for operating mode “MS: Velocity mode”.
• Direction of rotation according to sign.
• Standard setpoint source for operating mode is selected in
P201.01
.
P440.01
AO1 output area
Disabled
[0]
Definition of the output range.
0 ... 10 VDC
[1]
0 ... 5 VDC
[2]
2 ... 10 VDC
[3]
4 ... 20 mA
[4]
0 ... 20 mA
[5]
Default setting = bold print | * Default setting is device-dependent