Maintenance
Important notes
7
52
Lenze ¯ MA 12.0018 ¯ 4.1
7
Maintenance
7.1
Important notes
Note!
¯ Gearboxes below 200 Nm are lubricated for life.
¯ The mechanical power transmission system is maintenance−free.
¯
Before commissioning remove transport locking devices and keep them for later
transports.
¯
Take safety measures prior to any operation:
–
Disconnect the machine from the mains, ensure standstill of the drive system
and avoid any machine movement.
–
That the ambient temperature match the data on the nameplate.
7.2
Maintenance intervals
Stop!
For drive systems: Also observe the maintenance intervals for the other
drive components!
Dust deposits prevent heat to be emitted and cause a high housing temperature. The
gearboxes/geared motors must be purified of dirt and dust at regular intervals.
¯
In the case of gearboxes that are not lubricated for life, the lubricant must be
replaced at regular intervals.
–
The type of lubricant is indicated on the nameplate. Replace the lubricant only
with the same type of lubricant.
–
The lubricant change depends on the lubricant temperature, see Fig. 18.
1. Measure the lubricant temperature at the drain plug,
2. Add 10 °C,
3. Read the changing interval from the diagram.