Mechanical installation
Preparation
20
Lenze ¯ MA 12.0018 ¯ 4.1
4.3
Preparation
¯
Protect shaft sealing rings against contact with solvents!
¯
Thoroughly remove anticorrosion agents from the output shaft and from flange
faces.
¯
Repair paintwork damage.
¯
In some cases, due to lack of space, stud bolts with nuts must be used instead of
head screws. In these cases, contact Lenze, if necessary.
Tighten all screw connections with the torques given and lock them with standard
screw locking adhesive!
Thread
M3
M4
M5
M6
M8
M10
M12
M16
M20
M24
M27
M30
M36
Strength
Tightening torque [Nm]
4.8
0.7
1.4
2.8
4.8
12
23
−
−
−
−
−
−
−
8.8
1.3
3.0
5.9
10.1
24.6
48
84
206
415
714
1050 1428 2482
10.9
1.9
4.6
8.6
14.9
36.1
71
123
302
592
1017 1496 2033 3535
Tab. 1
Tightening torques for friction factor
m
= 0.12; tolerance of the tightening torque ±10 %
Please note: increase the tightening torque by 10% for screwed connections with flat
gaskets.
Correcting the lubricant amount
If the oil quantity in the gearbox has been increased for long−term storage ( (
10) , the
oil must be drained completely and must then be refilled for the intended mounting
position. (
52). Carry out the following steps:
1. Place receptacle under oil drain plug.
2. Remove breathing / oil filler plug.
3. Completely drain lubricant.
4. Screw in oil drain plug.
5. Fill gearbox with correct oil quantity for intended mounting position (according to
nameplate).
6. Screw in ventilation / oil filler plug.
Condensation drain hole
Note!
Lenze delivers motors with condensation drain holes with sealed
condensation drain holes. The holes are sealed with a plastic plug or a
locking screw. This does not affect the type of protection and the motor is
protected against the ingress of foreign substances during transport and
operation. Further information, (