Parameter reference
Parameters of the Communication Unit
102
Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 3.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13862
C13863
C13870
Parameter | Name:
C13862 | CIP Network Status
Data type: UNSIGNED_16
Index: 10713 = 0x29D9
Display of the current CIP network status
• The status is also indicated via the
NS
LED.
Selection list
(read only)
0 No IP Address
1 Nonexistent
2 Established
3 Timed Out
4 Duplicate IP
5 Self-Test
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13863 | Ethernet Port
Data type: UNSIGNED_16
Index: 10712 = 0x29D8
Display of the baud rate currently used on the Ethernet connections
Selection list
(read only)
0 Nonexistent
1 10 Mbps/Half Duplex
2 10 Mbps/Full Duplex
3 100 Mbps/Half Duplex
4 100 Mbps/Full Duplex
5 Reserved
6 Reserved
Subcodes
Info
C13863/1
Ethernet port X31 link state
C13863/2
Ethernet port X32 link state
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13870 | CIP Connections State
Data type: UNSIGNED_16
Index: 10705 = 0x29D1
Display of the current CIP connection status
Selection list
(read only)
0 Nonexistent
3 Established
4 Timed Out
Subcodes
Info
C13870/1
Status of CIP connection 1
...
...
C13870/8
Status of CIP connection 8
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT