Parameter reference
Parameters of the Communication Unit
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13851
C13858
C13861
Parameter | Name:
C13851 | All words from scanner
Data type: INTEGER_16
Index: 10724 = 0x29E4
Display of the I/O data words transferred from the scanner to the Communication Unit (adapter).
In the subcodes, all I/O data words transferred from the scanner are displayed. However, only the configured I/O
data words are valid.
Display range
(min. value | unit | max. value)
-32768
32767
Subcodes
Info
C13851/1
...
C13851/8
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13858 | Ethernet Port Statistics
Data type: UNSIGNED_32
Index: 10717 = 0x29DD
Display of statistical values for the data transfer via the Ethernet connections
Subcodes
Info
C13858/1
Ethernet port X31: RX
C13858/2
Ethernet port X31: RX CRC error
C13858/3
Ethernet port X31: RX discarded
C13858/4
Ethernet port X31: TX
C13858/5
Ethernet port X31: TX discarded
C13858/6
Ethernet port X32: RX
C13858/7
Ethernet port X32: RX CRC error
C13858/8
Ethernet port X32: RX discarded
C13858/9
Ethernet port X32: TX
C13858/10
Ethernet port X32: TX discarded
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13861 | CIP Module Status
Data type: UNSIGNED_16
Index: 10714 = 0x29DA
Display of the current CIP module status
(Instance attribute 8 (State) in the
)
• The status is also indicated via the
MS
LED.
Selection list
(read only)
0 Nonexistent
1 Device Self Testing
2 Standby
3 Operational
4 Major Recoverable Fault
5 Major Unrecoverable Fault
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT