Technical data
General data and operating conditions
95
EDKCSDX064 DE/EN/FR 4.0
Environmental conditions
Climate
3k3 in accordance with IEC/EN
60721−3−3
Condensation, splash water and ice
formation not permissible.
Storage
IEC/EN 60721−3−1
1K3 (−25 ... + 55 °C)
Transport
IEC/EN 60721−3−2
2K3 (−25 ... +70 °C)
Operation
IEC/EN 60721−3−3
3K3 (0 ... + 55 °C)
l
Atmospheric pressure: 86 ... 106 kPa
l
Above +40 °C: reduce the rated
output current by 2 %/°C.
Site altitude
0 ... 4000 m amsl
l
Reduce rated output current by
5 %/1000 m above 1000 m amsl.
l
Over 2000 m amsl: Use is only
permitted in environments with
overvoltage category II
Pollution
EN 61800−5−1, UL840: Degree of pollution 2
Vibration resistance
Acceleration resistant up to 0.7 g (Germanischer Lloyd, general conditions)