During installation the notes given in the documentation for the standard
device must be observed!
Stop!
Requirements on the brake cable (connection BD1/BD2):
ƒ
If the brake cable is part of the motor cable, it must be shielded.
– An operation with unshielded brake cables can destroy the motor brake
control module.
– We recommend the use of Lenze system cables (motor cable with
separately shielded additional cores).
– Connect the shield to PE on both sides.
ƒ
When using a permanent magnet holding brake, ensure the correct
polarity of the brake cable.
– If the terminals are reversed, the brake does not release. Since the motor
runs against the closed brake, the brake can be destroyed.