Lenze · Inverter Drive 8400 motec (PROFINET® option) · DMS 5.0 EN · 02/2019 · TD23
81
13
Parameter reference
13.2
Parameters relevant for PROFINET communication
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13864
C13867
Parameter | Name:
C13864 | Active station name
Data type: VISIBLE_STRING
Index: 10711
d
= 29D7
h
Displays the active station name used by the inverter.
It may differ from the contents of code
, depending on whether the station name has been changed via the
fieldbus or via
Subcodes
Info
C13864/1
1st ... 30th character
C13864/2
31th ... 60th character
C13864/3
61th ... 90th character
C13864/4
91th ... 120th character
C13864/5
121th ... 150th character
C13864/6
151th ... 180th character
C13864/7
181th ... 210th character
C13864/8
211th ... 240th character
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13867 | Display: Most recent diagnostic data
Data type: OCTET_STRING
Index: 10708
d
= 29D4
h
Display of the diagnostic data sent by the inverter most recently.
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Bytes
Information
0
Slot
1
2
Subslot
3
4
Error code
...
7
8
Slot
9
10
Subslot
11
12
Error code
...
15