background image

9372BB hand terminal for 9300

ba_VPTOabLMMPVQTPR

P

Segment

Explanation

Code number

Four-digit code number

Subcode num-

ber

Two-digit subcode number

Parameters

Parameter value with max. twelve digits

Text

Help text with max. 13 digits;

in the operating level: status information of C0183 or contents of C0004

RDY

on

Ready for operation

off

Initialization or error

IMP

on

Power outputs inhibited

off

Power outputs enabled

Fail

on

Active fault

off

No fault

I

max

on

Motor current setpoint

²

C0022

off

Motor current setpoint <

C0022

M

max

on

Speed controller 1 within its limits
Drive is torque controlled

off

Drive is speed-controlled

SH PRG

SH PRG

Parameter accepted by SHIFT+PRG only (OFFLINE)

SH PRG

Parameter accepted by SHIFT+PRG only when controller is inhibited (OFFLINE)
Parameter is immediately accepted by controller (ONLINE)

empty

Parameter cannot be changed

hÉó ÑìåÅíáçåë

Òpefcq H Ò ãÉ~åëW
NK mêÉëë íÜÉ pefcq âÉó ~åÇ âÉÉé áí éêÉëëÉÇ
OK mêÉëë íÜÉ ëÉÅçåÇ âÉó

Keys

Function
Menu level

Code level

Parameter level/operating

level

PRG

-

Change between code, parameter and operating level

SHIFT+PRG

-

-

Accept parameters (depending

on the parameter and menu)

Y

next higher menu item

next higher code number

increase displayed number

SHIFT+

Y

next higher menu item fast

increase code number fast

increase displayed number fast

B

next lower menu item

next lower code number

decrease displayed number

SHIFT+

B

next lower menu item fast

decrease code number fast

decrease displayed number

fast

A

next higher menu level

go to the menu level

Cursor to the left

"

next lower menu level (subme-

nus) or code level

-

Cursor to the right

RUN

cancel function of the STOP key

STOP

Controller inhibit: quick stop, controller inhibited or switched off C0469
The LED in the key shows the status of the STOP key:

D

LED on: STOP key pressed

D

LED off: RUN key pressed

Содержание 9372BB

Страница 1: ...mb mb uQ uR uS uT uU uV uNM ef il dka OU bN bO bP bQ bR PV N O P Q pq pq RV N O T SO P Q T SP N R R N R N N R mq qN qO mb r s t däçÄ ä aofsb oav fjm fã ñ jã ñ c áä pe mod m ê O m ê MMRN NORM êéã j qoiJkJ q pefcq mod pqlm hPRKMMNP ork HOQs ...

Страница 2: ...òì dÉê í áëí åáÅÜí ã ÖäáÅÜ D däÉáÅÜÉ e åÇÜ ÄìåÖ îçå e åÇíÉêãáå ä VPTO__ ìåÇ _ÉÇáÉåãçÇìä VPTN__K åëÅÜäì Belegung Farbe Anschluß Gelb CAN HI Grün CAN LO Braun GND1 Weiß 24V páÉÜÉ ìÅÜ _ÉíêáÉÄë åäÉáíìåÖ VPMM h éáíÉä QK fåÄÉíêáÉÄå ÜãÉ NK k _ ìÇê íÉ ÉáåëíÉääÉå Eåìê ïÉåå ÄïÉáÅÜÉåÇ îçå tÉêâë ÄÖäÉáÅÜ ÉáåÖÉëíÉääíFK OK k ÇêÉëë EdÉê íÉ ÇêÉëëÉ F ÉáåëíÉääÉåK _ÉÇáÉåìåÖ i aJ åòÉáÖÉ pe mod m ê MMRN oav fjm fã ñ jã...

Страница 3: ... aáÉ åÖ ÄÉ Òpefcq H Ò ÄÉÇÉìíÉíW NK q ëíÉ pefcq ÇêΩÅâÉå ìåÇ ÖÉÇêΩÅâí Ü äíÉå OK aáÉ òïÉáíÉ åÖÉÖÉÄÉåÉ q ëíÉ ÇêΩÅâÉå Tasten Funktion Menüebene Codeebene Parameterebene Betriebse bene PRG Wechseln zwischen Code Paramter und Betriebsebene SHIFT PR G Parameter übernehmen abhän gig vom Parameter und Menü Y nächst höheren Menüpunkt nächst höhere Codenummer angezeigte Zahl vergrößern SHIFT Y schnell nächst ...

Страница 4: ...çåÉ ÅçåíêçääÉê íç íÜÉ çíÜÉê D qÜÉ Ü åÇäáåÖ çÑ íÜÉ VPTO__ Ü åÇ íÉêãáå ä áë íÜÉ ë ãÉ ë Ñçê íÜÉ VPTN__ âÉóé ÇK çååÉÅíáçå Assignment Colour Connection Yellow CAN HI Green CAN LO Brown GND1 White 24V pÉÉ äëç ÅÜ éíÉê Q áå íÜÉ VPMM léÉê íáåÖ fåëíêìÅíáçåëK çããáëëáçåáåÖ NK k Ä ìÇ ê íÉ ëÉííáåÖ Eçåäó áÑ ÇáÑÑÉêÉåí Ñêçã ÇÉÑ ìäí ëÉííáåÖFK OK k ÇÇêÉëë EÅçåíêçääÉê ÇÇêÉëëF ëÉííáåÖK léÉê íáçå i a Çáëéä ó pe mod m ê...

Страница 5: ...ler ONLINE empty Parameter cannot be changed hÉó ÑìåÅíáçåë Òpefcq H Ò ãÉ åëW NK mêÉëë íÜÉ pefcq âÉó åÇ âÉÉé áí éêÉëëÉÇ OK mêÉëë íÜÉ ëÉÅçåÇ âÉó Keys Function Menu level Code level Parameter level operating level PRG Change between code parameter and operating level SHIFT PRG Accept parameters depending on the parameter and menu Y next higher menu item next higher code number increase displayed numb...