Configuration
2−83
l
EDSVF9383V−EXT EN 2.0
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
DCTRL−CINH1
d
C0878/1
bin
C0870/1
2
1000
HIGH = inhibit controller
DCTRL−CINH2
d
C0878/2
bin
C0870/2
2
1000
HIGH = inhibit controller
DCTRL−TRIP−SET
d
C0878/3
bin
C0871
2
54
HIGH = fault indication EEr
DCTRL−TRIPRESET
d
C0878/4
bin
C0876
2
55
LOW−HIGH signal = Trip reset
DCTRL−PAR*1
d
C0884/1
bin
C0880/1
2
1000
Select parameter set
DCTRL−PAR*2
d
C0884/2
bin
C0880/2
2
1000
Select parameter set
DCTRL−PAR−LOAD
d
C0884/3
bin
C0881
2
1000
LOW−HIGH signal = Load parameter set
DCTRL−RDY
d
−
−
−
−
−
HIGH = Ready for operation
DCTRL−CINH
d
−
−
−
−
−
HIGH = Controller reset
DCTRL−IMP
d
−
−
−
−
−
HIGH = High−resistance power output
stages
DCTRL−TRIP
d
−
−
−
−
−
HIGH = Active fault
DCTRL−WARN
d
−
−
−
−
−
HIGH = Active warning
DCTRL−MESS
d
−
−
−
−
−
HIGH = Active message
DCTRL−FAIL
d
−
−
−
−
−
−
DCTRL−CW/CCW
d
−
−
−
−
−
LOW = CW rotation, HIGH = CCW rotation
DCTRL−NACT=0
d
−
−
−
−
−
HIGH = Motor speed < C0019
DCTRL−STAT*1
d
−
−
−
−
−
general status (binary coded)
DCTRL−STAT*2
d
−
−
−
−
−
general status (binary coded)
DCTRL−STAT*4
d
−
−
−
−
−
general status (binary coded)
DCTRL−STAT*8
d
−
−
−
−
−
general status (binary coded)
DCTRL−INIT
d
−
−
−
−
−
−
DCTRL−PARBUSY
d
−
−
−
−
HIGH = Change of parameter set active
DCTRL−PAR*1−O
d
−
−
−
−
−
Parameter set X active (binary coded)
DCTRL−PAR*2−0
d
−
−
−
−
−
Parameter set X active (binary coded)
Range of functions
l
Quick stop (QSP)
l
Operation inhibited (DISABLE)
l
Controller inhibit (CINH)
l
TRIP−SET
l
TRIP−RESET
l
Changing the parameter set (PAR)
l
Controller state
2.4.22.1
Quick stop (QSP)
If QSP is activated, the drive is decelerated to zero speed via the deceleration ramp C0105.
l
QSP is activated via three inputs:
– Control word CAN−CTRL.B3 from CAN−IN1
– Control word AIF−CTRL.B 3 from AIF−IN
– Control word C0135.B3
l
All inputs are linked by an OR−operation
l
QSP can also be activated via the input MCTRL−QSP in the FB MCTRL.
Содержание 9300 vector Series
Страница 8: ...Preface Definition of notes used 1 6 l EDSVF9383V EXT EN 2 0...
Страница 188: ...Application examples Centre winder with internal diameter calculation 3 18 l EDSVF9383V EXT EN 2 0...
Страница 192: ...Signal flow charts Speed control 4 4 l EDSVF9383V EXT EN 2 0 Fig 4 1 Basic configuration 1000 speed control sheet 1...
Страница 205: ...Signal flow charts Step control 4 17 l EDSVF9383V EXT EN 2 0 Fig 4 13 Basic configuration 2000 step control sheet 1...
Страница 211: ...Signal flow charts Torque control 4 23 l EDSVF9383V EXT EN 2 0 Fig 4 17 Basic configuration 4000 torque control sheet 1...