Configuration
2−127
l
EDSVF9383V−EXT EN 2.0
2.4.42
Motor phase failure detection (MLP)
Purpose
Motor phase monitoring.
MLP1
Fig. 2−99
Motor phase failure detection (MLP1)
Code
LCD
Possible settings
IMPORTANT
Lenze
Selection
C0597 MONIT LP1
3
0
Trip
2
Warning
3
Off
Conf. LP1
Configuration of motor phase failure
monitoring
C0599 LIMIT LP 1
5.0
1.0
{0.1}
10.0
Current limit LP1
Current limit for motor phase failure
monitoring
Function
For detailed descriptions of the monitorings / error messages, please see the chapter
"Troubleshooting and fault elimination" in the System Manual.
The function block MLP1 must be entered into the processing table, if the motor phase failure
detection shall be used.