Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
235
8400 motec | Software Manual
Parameter reference
Parameter list | C00003
C00003
C00005
C00006
Parameter | Name:
C00003 | Status of last device command
Data type: UNSIGNED_8
Index: 24572
d
= 5FFC
h
Status of the device command carried out last (
Note:
Before switching off the supply voltage after carrying out a device command, check whether the device command
has been carried out successfully via the status display!
:
Selection list
(read only)
Info
0 Successful
Device command has been carried out successfully.
1 Command unknown
Device command is implausible or not known in the
system.
2 No access
Access for requested device command is not approved.
3 Time-out
Device command could not be processed in the defined
time (time-out).
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00005 | Application
Data type: UNSIGNED_16
Index: 24570
d
= 5FFA
h
Selection list
(Lenze setting printed in bold)
Info
1000 Actuating drive speed
This technology application is used to solve speed-
controlled drive tasks, e.g. conveying belts.
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00006 | Motor control
Data type: UNSIGNED_8
Index: 24569
d
= 5FF9
h
Selection of the motor control mode
:
Selection list
(Lenze setting printed in bold)
Info
4 SLVC: Vector control
This control type is used for sensorless vector control of
an asynchronous motor.
• The control type requires motor parameters to be set
as exactly as possible!
6 VFCplus: V/f linear
This control type is used for the speed control of an
asynchronous motor via a linear V/f characteristic and is
the simplest control type.
• For setting the V/f characteristic, only the rated
frequency (
) and the rated voltage (
) of
the motor have to be entered.
7 VFCplus: V/f encoder
From version 02.00.00
This control type is used for speed control of an
asynchronous motor via a linear V/f characteristic.
• This control type requires a speed feedback via an
encoder connected to the motor!
• For setting the V/f characteristic, only the rated
frequency (
) and the rated voltage (
) of
the motor have to be entered.
Содержание 8400 motec Series