Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
245
8400 motec | Software Manual
Parameter reference
Parameter list | C00084
C00084
C00085
C00087
C00088
C00089
Parameter | Name:
C00084 | Motor stator resistance
Data type: UNSIGNED_32
Index: 24491
d
= 5FAB
h
After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically. An automatic detection via the motor parameter identification is possible as well.
Setting range
(min. value | unit | max. value)
Lenze setting
0
mohm
200000
330 mohm
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 1
Parameter | Name:
C00085 | Motor stator leakage inductance
Data type: UNSIGNED_16
Index: 24490
d
= 5FAA
h
After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically. An automatic detection via the motor parameter identification is possible as well.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
mH
650.00
0.00 mH
;
Read access
;
Write access
;
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 100
Parameter | Name:
C00087 | Rated motor speed
Data type: UNSIGNED_16
Index: 24488
d
= 5FA8
h
This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor
catalogue, the suitable value can be entered automatically.
Note:
The indication of the rated motor speed is mandatory for the sensorless vector control (
Setting range
(min. value | unit | max. value)
Lenze setting
50
rpm
9999
1460 rpm
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 1
Parameter | Name:
C00088 | Rated motor current
Data type: UNSIGNED_16
Index: 24487
d
= 5FA7
h
This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor
catalogue, the suitable value can be entered automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
A
99.00
21.00 A
;
Read access
;
Write access
;
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 100
Parameter | Name:
C00089 | Rated motor frequency
Data type: UNSIGNED_16
Index: 24486
d
= 5FA6
h
This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor
catalogue, the suitable value can be entered automatically.
Note:
The indication of the rated motor frequency is mandatory for the sensorless vector control (
Setting range
(min. value | unit | max. value)
Lenze setting
10
Hz
1000
50 Hz
;
Read access
;
Write access
;
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 1