8400 motec | Software Manual
Parameter reference
Structure of the parameter descriptions
232
L
Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
11.1.4
Parameter attributes
The table footers contain the parameter attributes:
Scaling factor
The "scaling factor" is important for parameter access via a bus system.
Example 1: The value "654" of the parameter
(AIN1: input voltage) read via a bus
system must be divided by the corresponding scaling factor "100" to obtain the actual
display value "6.54 V".
[11-1] Conversion formula for read access via bus system
Example 2: In order to set the parameter
(acceleration time - main setpoint) to the
value "123.4 s" via a bus system, the integer value "123400" must be transferred, i.e. the
value to be set must be multiplied by the corresponding scaling factor "1000".
[11-2] Conversion formula for write access via bus system
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Attribute
Meaning
;
Read access
Read access to parameter possible.
;
Write access
Write access to parameter possible.
• Please also observe the following attributes:
;
CINH
Parameter value can only be changed when the controller is
inhibited.
;
PLC STOP
Parameter value can only be changed when the application is
stopped.
;
No transfer
Parameter is
not
transferred to controller when the command Download parameter set is
executed.
;
COM
Communication-relevant parameter
• This parameter is relevant for parameter data transfer via the (CAN) system bus.
;
MOT
Motor control parameters
Signal type
Scaling factor
Resolution
Value range
Analog (scaled)
100
16 bits signed
± 199.99 %
Angular velocity
1
16 bits signed
± 32767 incr./ms
Position in [units]
10000
32 bits signed
± 214748.3647 [units]
Digital (BOOL)
1
8 bits unsigned
0
≡
FALSE; 1
≡
TRUE
Time
1000
16 bits unsigned
0 ... 999.000 s
Selection value
1
16 bits unsigned
0 ... 65535
Read value (via bus system)
Scaling factor
-----------------------------------------------------------------------
Indicated value (Engineer)
=
Value to be written (via bus system)