8400 motec | Software Manual
Parameter reference
Parameter list | C00023
240
L
Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
C00023
C00024
C00026
C00027
C00028
Parameter | Name:
C00023 | Imax in generator mode
Data type: INTEGER_16
Index: 24552
d
= 5FE8
h
Maximum current in generator mode for all motor control modes
• 100 %
≡
Imax in motor mode (
)
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
%
100.0
100.0 %
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00024 | Comparison value N_Act
Data type: INTEGER_16
Index: 24551
d
= 5FE7
h
Threshold for the actual speed comparison
• This parameter serves to set a threshold that is compared with the actual speed value.
• When the value falls below this threshold, the
bNactCompare
output of the SB
switches to
TRUE.
• Switching hysteresis = +1 %
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
%
199.9
0.0 %
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00026 | AINx: Offset
Data type: INTEGER_16
Index: 24549
d
= 5FE5
h
Offset for analog input
Setting range
(min. value | unit | max. value)
-199.9
%
199.9
Subcodes
Lenze setting
Info
C00026/1
0.0 %
AIN1: Offset
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00027 | AINx: Gain
Data type: INTEGER_32
Index: 24548
d
= 5FE4
h
Gain for analog input
Setting range
(min. value | unit | max. value)
-199.9
%
199.9
Subcodes
Lenze setting
Info
C00027/1
100.0 %
AIN1: Gain
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00028 | AINx: Input voltage
Data type: INTEGER_16
Index: 24547
d
= 5FE3
h
Display of the input voltage at the analog input
Display range
(min. value | unit | max. value)
-10.0
V
10.0
Subcodes
Info
C00028/1
AIN1: Input voltage
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Содержание 8400 motec Series