
Configuration
UOMu_^MVMO
7-9
Code
IMPORTANT
Possible settings
Name
Code
IMPORTANT
Info
Selection
Lenze
Name
C117
¿
Function relay
K2
822X/824X
-0-
-0- Ready for operation
-1- TRIP fault message
-2- Motor is running
-3- Motor is running / CW rotation
-4- Motor is running / CCW rotation
-5- Field frequency f
d
= 0
-6- f
dSet
reached
-7- Q
min
reached
-8- I
max
reached
-9- Overtemperature (
J
max
-10
°
C)
-10- TRIP or Q
min
or IMP
-11- PTC warning
C119
¿
Function PTC
822X/824X
-0-
-0- PTC input inactive
-1- PTC input active,
TRIP and IMP (pulse inhibit) are set
-2- PTC input active, warning
C120 I
2
¡
t switch off
822X/824X
0
0
{1 %}
100
C125
¿
*
LECOM baud
rate
-0-
-0- 9600 baud
-1- 4800 baud
-2- 2400 baud
-3- 1200 baud
-4- 19200 baud
Only for
LECOM
applications
C142
¿
Start condition
-1-
-0- Automatic start inhibited, flying-restart
circuit inactive
-1- Automatic start, if term. 28 HIGH,
flying-restart circuit not active
-2- Automatic start inhibited, flying-restart
circuit active
-3- Automatic start, if term. 28 HIGH,
flying-restart circuit active
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com