36
YOGA 500-14ISK/YOGA 500-15ISK Hardware Maintenance Manual
Figure 2. Removal steps of battery pack (continued)
YOGA 500-15ISK
Unplug the battery connector in the direction shown by arrow
1
, then remove
the screws
2
. Remove the battery pack
3
.
1
2
2
3
Step
Screw (quantity)
Color
Torque
2
M2.0 × 2.5 mm, Phillips head, nylok-coated (2)
Battery to UCASE (YOGA 500-15ISK)
Black
2.0 kgf*cm
When installing:
Make sure that the connectors are attached firmly.