806f060d-040dffff : Array [ComputerSystemElementName] has failed. (Drive 13)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d040dffff or 0x806f060d040dffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
•
806f060d-040effff : Array [ComputerSystemElementName] has failed. (Drive 14)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d040effff or 0x806f060d040effff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Appendix A. Integrated management module II (IMM2) error messages
503
Содержание x3300 M4 7382
Страница 1: ...System x3300 M4 Installation and Service Guide Machine Type 7382 ...
Страница 6: ...iv System x3300 M4 Installation and Service Guide ...
Страница 14: ...xii System x3300 M4 Installation and Service Guide ...
Страница 166: ...152 System x3300 M4 Installation and Service Guide ...
Страница 176: ...162 System x3300 M4 Installation and Service Guide ...
Страница 704: ...690 System x3300 M4 Installation and Service Guide ...
Страница 888: ...874 System x3300 M4 Installation and Service Guide ...
Страница 896: ...Taiwan BSMI RoHS declaration 882 System x3300 M4 Installation and Service Guide ...
Страница 906: ...892 System x3300 M4 Installation and Service Guide ...
Страница 907: ......
Страница 908: ......