Server model: four 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, the rear hot-swap drive
assembly, one 16i RAID adapter
Figure 25. Cable routing for server models with four 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, the rear hot-
swap drive assembly, and one 16i RAID adapter
Cable
From
To
1
Power cable for front backplane
Power connector on front backplane
Backplane power connector 1 on the
system board
2
SAS signal cable for front
backplane
SAS 0 and SAS 1 connectors on front
backplane
C0 and C1 connectors on the 16i
RAID adapter installed on the RAID
adapter slot
3
NVMe signal cable for front
backplane
NVMe 0, NVMe 1, NVMe 2, and
NVMe 3 connectors on front
backplane
NVMe 0–1 and NVMe 2–3 connectors
on the system board
4
SAS signal cable for the rear hot-
swap drive assembly
Signal connector on the rear hot-
swap drive assembly
C2 connector on the 16i RAID
adapter installed on the RAID adapter
slot
.
37
Содержание ThinkSystem SR650
Страница 1: ...ThinkSystem SR650 Maintenance Manual Machine Types 7X05 and 7X06 ...
Страница 8: ...vi ThinkSystem SR650 Maintenance Manual ...
Страница 20: ...12 ThinkSystem SR650 Maintenance Manual ...
Страница 96: ...88 ThinkSystem SR650 Maintenance Manual ...
Страница 154: ...Figure 107 Riser 1 assembly removal 146 ThinkSystem SR650 Maintenance Manual ...
Страница 157: ...Figure 111 Installing the screws to secure the riser card Chapter 3 Hardware replacement procedures 149 ...
Страница 212: ...204 ThinkSystem SR650 Maintenance Manual ...
Страница 230: ...222 ThinkSystem SR650 Maintenance Manual ...
Страница 234: ...226 ThinkSystem SR650 Maintenance Manual ...
Страница 243: ......
Страница 244: ......