© Copyright Lenovo 2019
Chapter 4: Removing and Replacing Components
73
3.
Set the new switch to use the Machine Type-Model (MTM) number of the old unit:
where
1234-56X
is the MTM from your old unit.
Note:
The MTM (
1234-56X
) shown here is merely an example. Use the actual
MTM recorded from your old NE1072T unit.
4.
Set the new switch to use the serial number of the old unit:
where
XX01234
is the serial number of your old unit.
Note:
The serial number (
XX01234
) shown here is merely an example. Use the
actual serial number recorded from your old NE1072T unit.
5.
Reset the switch using the following command:
When prompted for confirmation, enter
y
. The switch then restarts.
6.
After the switch reboots, return to the command prompt and verify that the VPD
information is correct using the following command:
For more information about using the switch interface, see the
Application Guide
and
Command Reference
for the NE1072T and its corresponding Lenovo Network
Operating System and firmware version.
NE1072T(config)#
hardware mtm
1234-56X
New MTM value: 1234-56X
Please reset the system for the new changes to take effect
NE1072T(config)#
hardware esn
XX01234
NE1072T#
reload
NE1072T>
show sys-info
*** show boot ***
Current ZTP State: Enable
Current FLASH software:
active image: version 10.8.5.0, downloaded 13:02:51 UTC Mon Oct 22 2018
standby image: version 10.8.5.0, downloaded 13:03:50 UTC Sat Oct 20 2018
Grub: version 10.8.5.0, downloaded 13:02:53 UTC Mon Oct 22 2018
BIOS: version 0203B, release date 08/28/2018
Secure Boot: Disabled
ONIE: version unknown, downloaded unknown
Currently set to boot software active image
Currently scheduled reboot time: none
...
System Name : NE1072T
System Description : NE1072T
System Model : Lenovo ThinkSystem NE1072T RackSwitch
System VPD Version : 3.1
System Manufacture Date : 2918 (WWYY)
System Part Number : SSG7A38810
System Serial Number : 00000000000
System FRU Number : 01PF000
System Machine Type Model : 7Y81CTO2WW
System Machine Serial Number : MMM0000000
System Hardware Revision : 3
System Management MAC : 3C:2C:99:F8:91:40
...
Содержание ThinkSystem NE1072T
Страница 1: ...Lenovo ThinkSystem NE1072T RackSwitch Installation Guide For Lenovo Cloud Network Operating System ...
Страница 6: ...6 Lenovo NE1072T Installation Guide ...
Страница 16: ...16 NE1072T Installation Guide ...
Страница 21: ... Copyright Lenovo 2019 21 Chapter 2 Switch Components This chapter describes the NE1072T hardware components ...
Страница 56: ...56 NE1072T Installation Guide ...
Страница 74: ...74 NE1072T Installation Guide ...
Страница 90: ...90 NE1072T Installation Guide ...
Страница 96: ...96 NE1072T Installation Guide ...
Страница 112: ...112 NE1072T Installation Guide ...
Страница 118: ...118 NE1072T Installation Guide ...