CRU replacement for 5U chassis 133
CRU replacement for 5U chassis
NOTE:
Unless noted otherwise within a passage pertaining to a particular CRU, the replacement procedure
should be completed within two minutes of the removal of the defective module.
Accessing drawers
To observe or replace a DDIC, you must open the drawer in which it resides. The top drawer (Drawer 0) and the
bottom drawer (Drawer 1) are accessed from the enclosure front panel. See also
.
Opening a drawer
1.
Verify that the anti-tamper locks are not engaged. The red arrows on the locks point inward if the locks are
disengaged as shown in
. If necessary, unlock them by rotating counter-clockwise using a Torx T20
bit.
Figure 92 Drawer front panel details
2.
Push the drawer latches inward and hold them as shown in
Figure 93 Opening a drawer (1 of 2)