Installing a storage drive into drive bay 4
Note:
For a 2.5-inch hard disk drive or solid-state drive, install the drive into a 2.5-inch to 3.5-inch drive
adapter first. See “Installing a 2.5-inch drive into a 2.5-inch to 3.5-inch drive adapter” on page 46.
To install a storage drive into drive bay 4, do the following:
1. Prepare your server. See “Preparing your server and removing the server cover” on page 41.
2. Remove the front bezel. See “Removing the front bezel” on page 42.
3. If there is a metal shield covers the drive bay, remove the metal shield. Save the metal shield in case
that you later remove the drive and need the metal shield to cover the drive bay.
4. Flex the sides of the drive bracket and align pins
1
,
2
,
3
, and
4
on the bracket with the corresponding
holes in the drive. Do not touch the circuit board
5
on the bottom of the drive.
1
2
3
4
5
Figure 42. Installing the drive into the drive bracket
5. Install the drive into the 5.25-inch convertor kit.
1
Squeeze the release buttons as shown to open the rear cover of the convertor kit.
2
Slide the drive into the convertor kit until it snaps into position. Then, close the rear cover.
1
2
Figure 43. Installing the drive into the convertor kit
.
63
Содержание ThinkServer TS150
Страница 14: ...xii ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 52: ...38 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 116: ...102 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 124: ...110 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 135: ...Taiwan BSMI RoHS declaration Appendix C Restriction of Hazardous Substances RoHS Directive 121 ...
Страница 136: ...122 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 146: ...132 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 147: ......
Страница 148: ......