To complete the parts replacement, go to “Completing the parts replacement” on page 95.
M.2 solid-state drive
•
“Removing the M.2 solid-state drive” on page 65
•
“Installing the M.2 solid-state drive” on page 65
Removing the M.2 solid-state drive
To remove the M.2 solid-state drive (SSD), do the following:
1. Prepare your server. See “Preparing your server in advance” on page 47.
2. If the server is installed with a PCIe card, remove the card. See “Removing the PCIe card” on page 56.
3. Locate the M.2 SSD and remove the screw that secures it. Then, lift it up to remove it from the system
board.
Figure 41. Removing the M.2 SSD
4. Reinstall the PCIe card if you have removed it. See “Installing the PCIe card” on page 56.
5. If you are instructed to return the old M.2 SSD, follow all packaging instructions and use any packaging
materials that are supplied to you for shipping.
To complete the parts replacement, go to “Completing the parts replacement” on page 95.
Installing the M.2 solid-state drive
To install the M.2 SSD, do the following:
1. Prepare your server. See “Preparing your server in advance” on page 47.
2. If the server is installed with a PCIe card, remove the card. See “Removing the PCIe card” on page 56.
3. If the server comes with an old M.2 SSD, remove the old M.2 SSD. See “Removing the M.2 solid-state
4. Touch the static-protective package that contains the new M.2 SSD to any unpainted surface on the
outside of the server. Then, take the M.2 SSD out of the package.
.
65
Содержание ThinkServer RS160
Страница 1: ...ThinkServer RS160 User Guide and Hardware Maintenance Manual Machine Types 70TD 70TE 70TF and 70TG ...
Страница 14: ...xii ThinkServer RS160 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer RS160 User Guide and Hardware Maintenance Manual ...
Страница 42: ...28 ThinkServer RS160 User Guide and Hardware Maintenance Manual ...
Страница 58: ...44 ThinkServer RS160 User Guide and Hardware Maintenance Manual ...
Страница 118: ...104 ThinkServer RS160 User Guide and Hardware Maintenance Manual ...
Страница 129: ...Taiwan BSMI RoHS declaration Appendix C Restriction of Hazardous Substances RoHS Directive 115 ...
Страница 130: ...116 ThinkServer RS160 User Guide and Hardware Maintenance Manual ...
Страница 141: ......
Страница 142: ......