LSI Corporation
- 314 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 11: Maintaining and Managing Storage Configurations
Running a Consistency Check
Figure 196 Group Initialization Dialog
2.
Either check the virtual drives on which to run the initialization, or click
Select All
to select all of the virtual drives.
3.
Click
Start
.
You can monitor the progress of the group initialization. See
Monitoring Rebuilds and Other Processes
for more
information.
11.2
Running a Consistency Check
You should periodically run a consistency check on fault-tolerant virtual drives (RAID 1, 5, 6, 10, 50, or 60
configurations; RAID 0 does not provide data redundancy). A consistency check scans the virtual drive to determine
whether the data has become corrupted and needs to be restored.
For example, in a system with parity, checking consistency means computing the data on one drive and comparing
the results to the contents of the parity drive. You must run a consistency check if you suspect that the data on the
virtual drive might be corrupted.
NOTE
Make sure to back up the data before running a consistency check if
you think the data might be corrupted.