LSI Corporation
- 163 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 6: StorCLI
Working with the Storage Command Line Tool
Table 38 Properties for Show and Set Commands
Property Name
Set Command Range
Description
abortcconerror
on|off
Aborts consistency check when it detects an
inconsistency.
activityforlocate
on|off
Enables/disables drive activity, drive activity
locates function for systems without SGPIO/SES
capabilities.
alarm
on|off|silence
silence
: Silences the alarm.
Enables/disables alarm on critical errors.
batterywarning
on|off
Enables/disables battery warnings.
bgirate
0 to 100
Sets background initialization rate in percentage.
cacheflushint
0 to 255, default value
4
Sets cache flush interval in seconds.
ccrate
0 to 100
Sets consistency check rate in percentage.
coercion
0
: No coercion
1
: 128 MB
2
: 1 GB
Sets drive capacity in coercion mode.
consistencycheck
See
.
See
.
copyback
on|off
type = smartssd|smarthdd|all
smartssd
: Copy back enabled for SSD
drives.
smarthdd
: Copy back enabled for HDD
drives.
all
: Copy back enabled for both ssd drives
and HDD drives.
Example:
storcli /cx set copyback=on
type=all
Enables/disables copy back for drive types.
directpdmapping
on|off
Enables/disables direct physical drive mapping.
When enclosures are used, this feature is
disabled; otherwise it should be enabled.
eccbucketleakrate
0 to 65535
Sets leak rate of the single-bit bucket in minutes
(one entry removed per leak-rate).
eccbucketsize
0 to 255
Sets size of ECC single-bit-error bucket (logs
event when full).
eghs state
on|off
Enables/disables the commissioning of
otherwise incompatible global hot spare drives
as Emergency Hot Spare (EHSP) drives.
eghs smarter
on|off
Enables/disables the commissioning of
Emergency Hot Spare (EHSP) drives for Predictive
Failure (PFA) events.
eghs eug
on|off
Enables/disables the commissioning of
Unconfigured Good drives as Emergency Hot
Spare (EHSP) drives.
backplane mode
0
: Use autodetect logic of backplanes, such
as SGPIO and I2C SEP using GPIO pins.
1
: Disable autodetect SGPIO.
2
: Disable I2C SEP autodetect.
3
: Disable both the autodetects.
Configures enclosure detection on a
non-SES/expander backplane.
backplane expose
on|off
Enables/disables device drivers to expose
enclosure devices; for example, expanders, SEPs.
Содержание ThinkServer RD650