Diagnostic error codes
Refer to the following diagnostic error codes when using the diagnostic tests. See
“Running tests” on page 46 for the specific type for information about the
Diagnostic programs.
In the following index,
X
can represent any number.
Diagnostic Error Code
FRU/Action
000-000-XXX
BIOS Test Passed
No action
000-002-XXX
BIOS Timeout
1.
Flash the system. See “Flash update
procedures” on page 533
2.
System board
000-024-XXX
BIOS Addressing test failure
1.
Flash the system. See “Flash update
procedures” on page 533
2.
System board
000-025-XXX
BIOS Checksum Value error
1.
Flash the system. See “Flash update
procedures” on page 533
2.
System board
000-026-XXX
FLASH data error
1.
Flash the system. See “Flash update
procedures” on page 533
2.
System board
000-027-XXX
BIOS Configuration/Setup error
1.
Run Setup
2.
Flash the system. See “Flash update
procedures” on page 533
3.
System board
000-034-XXX
BIOS Buffer Allocation failure
1.
Reboot the system
2.
Flash the system. See “Flash update
procedures” on page 533
3.
Run memory test
4.
System board
000-035-XXX
BIOS Reset Condition detected
1.
Flash the system. See “Flash update
procedures” on page 533
2.
System board
000-036-XXX
BIOS Register error
1.
Flash the system. See “Flash update
procedures” on page 533
2.
System board
000-038-XXX
BIOS Extension failure
1.
Flash the system. See “Flash update
procedures” on page 533
2.
Adapter card
3.
System board
000-039-XXX
BIOS DMI data error
1.
Flash the system. See “Flash update
procedures” on page 533
2.
System board
000-195-XXX
BIOS Test aborted by user
Information only
Restart the test, if necessary
54
Hardware Maintenance Manual
Содержание ThinkCentre
Страница 1: ......
Страница 2: ......
Страница 3: ...ThinkCentre Hardware Maintenance Manual ...
Страница 17: ...Chapter 2 Safety information 11 ...
Страница 18: ...12 Hardware Maintenance Manual ...
Страница 19: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 Chapter 2 Safety information 13 ...
Страница 23: ...Chapter 2 Safety information 17 ...
Страница 24: ...1 2 18 Hardware Maintenance Manual ...
Страница 25: ...Chapter 2 Safety information 19 ...
Страница 26: ...1 2 20 Hardware Maintenance Manual ...
Страница 33: ...Chapter 2 Safety information 27 ...
Страница 34: ...28 Hardware Maintenance Manual ...
Страница 35: ...1 2 Chapter 2 Safety information 29 ...
Страница 39: ...Chapter 2 Safety information 33 ...
Страница 40: ...1 2 34 Hardware Maintenance Manual ...
Страница 44: ...38 Hardware Maintenance Manual ...
Страница 48: ...42 Hardware Maintenance Manual ...
Страница 106: ...5 Go to Completing the FRU replacement on page 121 100 Hardware Maintenance Manual ...
Страница 128: ...122 Hardware Maintenance Manual ...
Страница 158: ...3 Remove the new adapter card from its static protective package 152 Hardware Maintenance Manual ...
Страница 434: ...7413 Windows 7 Starter 32 Recovery DVDs FRU CRU English models 71Y7399 1 428 Hardware Maintenance Manual ...
Страница 538: ...532 Hardware Maintenance Manual ...
Страница 545: ......
Страница 546: ...Part Number 53Y6397 Printed in USA 1P P N 53Y6397 ...