Diagnostic Error Code
FRU/Action
086-198-XXX
Mouse Port interface test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 47
2. Flash the system and re-test. See “Flash update
procedures” on page 375
3. Go to “Undetermined problems” on page 76
086-199-XXX
Mouse Port interface test failed, cause
unknown
1. See “Undetermined problems” on page 76
2. Flash the system and re-test. See “Flash update
procedures” on page 375
3. Replace component under function test
089-000-XXX
Microprocessor Test Passed
No action
089-XXX-XXX
Microprocessor failure
1.
Microprocessor(s)
2. System board
089-195-XXX
Microprocessor Test aborted by user
Information only
Re-start the test, if necessary
089-196-XXX
Microprocessor test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
089-197-XXX
Microprocessor test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 47
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
089-198-XXX
Microprocessor test aborted
1.
Flash the system. See “Flash update procedures”
on page 375
2. Go to “Undetermined problems” on page 76
089-199-XXX
Microprocessor test failed, cause unknown
1. See “Undetermined problems” on page 76
2. Flash the system and re-test. See “Flash update
procedures” on page 375
3. Replace component under function test
170-000-XXX
Voltage Sensor(s) Test Passed
No action
170-0XX-XXX
Voltage Sensor(s) failure
1.
Flash system
2. System board
170-195-XXX
Voltage Sensor(s) Test aborted by user
Information only
Re-start the test, if necessary
170-196-XXX
Voltage Sensor(s) test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
Chapter 7
.
Symptom-to-FRU Index
67
Содержание ThinkCentre M55
Страница 2: ......
Страница 17: ...Chapter 2 Safety information 11 ...
Страница 18: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 12 Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 22: ...1 2 16 Hardware Maintenance Manual ...
Страница 23: ...Chapter 2 Safety information 17 ...
Страница 29: ...Chapter 2 Safety information 23 ...
Страница 33: ...Chapter 2 Safety information 27 ...
Страница 42: ...36 Hardware Maintenance Manual ...
Страница 46: ...40 Hardware Maintenance Manual ...
Страница 56: ...50 Hardware Maintenance Manual ...
Страница 84: ...78 Hardware Maintenance Manual ...
Страница 380: ...374 Hardware Maintenance Manual ...
Страница 384: ...378 Hardware Maintenance Manual ...
Страница 387: ......
Страница 388: ...Part Number 41X6286 Printed in USA 1P P N 41X6286 41X6286 ...