Diagnostic Error Code
FRU/Action
030-196-XXX
SCSI interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
030-197-XXX
SCSI interface test warning
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 43
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
030-198-XXX
SCSI interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 43
2. Flash the system and re-test. See “Updating
(flashing) the BIOS from a disc” on page 217
3. Go to “Undetermined problems” on page 71
030-199-XXX
SCSI interface test failed, cause unknown
1. Go to “Undetermined problems” on page 71
2. Flash the system and re-test. See “Updating
(flashing) the BIOS from a disc” on page 217
3. Replace component under function test
035-000-XXX
RAID interface Test Passed
No action
035-0XX-XXX
RAID interface Failure
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
035-195-XXX
RAID interface Test aborted by user
Information only Re-start the test, if necessary
035-196-XXX
RAID interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
035-197-XXX
RAID interface test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 43
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
035-198-XXX
RAID interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 43
2. Flash the system and re-test. See “Updating
(flashing) the BIOS from a disc” on page 217
3. Go to “Undetermined problems” on page 71
035-199-XXX
RAID interface test failed, cause unknown
1. See “Undetermined problems” on page 71
2. Flash the system and re-test. See “Updating
(flashing) the BIOS from a disc” on page 217
3. Replace component under function test
071-000-XXX
Audio port Interface Test Passed
No action
Chapter 7
.
Symptom-to-FRU index
61
Содержание ThinkCentre Edge 71
Страница 1: ...ThinkCentre Hardware Maintenance Manual Machine Types 1577 1578 1579 1583 1607 and 1652 ...
Страница 6: ...2 ThinkCentre Hardware Maintenance Manual ...
Страница 13: ...Chapter 2 Safety information 9 ...
Страница 14: ... 18 kg 37 lb 32 kg 70 5 lb 55 kg 121 2 lb 10 ThinkCentre Hardware Maintenance Manual ...
Страница 18: ...14 ThinkCentre Hardware Maintenance Manual ...
Страница 19: ...1 2 Chapter 2 Safety information 15 ...
Страница 20: ...1 2 16 ThinkCentre Hardware Maintenance Manual ...
Страница 26: ...22 ThinkCentre Hardware Maintenance Manual ...
Страница 27: ...1 2 Chapter 2 Safety information 23 ...
Страница 31: ...Chapter 2 Safety information 27 ...
Страница 32: ...1 2 28 ThinkCentre Hardware Maintenance Manual ...
Страница 36: ...32 ThinkCentre Hardware Maintenance Manual ...
Страница 40: ...36 ThinkCentre Hardware Maintenance Manual ...
Страница 52: ...48 ThinkCentre Hardware Maintenance Manual ...
Страница 76: ...72 ThinkCentre Hardware Maintenance Manual ...
Страница 224: ...220 ThinkCentre Hardware Maintenance Manual ...
Страница 229: ......
Страница 230: ...Part Number 0B01241 1P P N 0B01241 1P0B01241 ...