Diagnostic error code
FRU/Action
000-197-XXX
BIOS test warning
1.
Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
000-198-XXX
BIOS test aborted
1.
Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 39
2. Flash the system and retest. See “Updating (flashing)
BIOS from a disc” on page 203
3. Go to “Undetermined problems” on page 65
000-199-XXX
BIOS test failed, cause unknown
1. Go to “Undetermined problems” on page 65
2. Flash the system and re-test
3. Replace component under function test
000-250-XXX
BIOS APM failure
1.
Flash the system. See “Updating (flashing) BIOS
from a disc” on page 203
2. System board
000-270-XXX
BIOS ACPI failure
1.
Flash the system. See “Updating (flashing) BIOS
from a disc” on page 203
2. System board
001-000-XXX
System Test Passed
No action
001-00X-XXX
System Error
System board
001-01X-XXX
System Error
System board
001-024-XXX
System Addressing test failure
System board
001-025-XXX
System Checksum Value error
1.
Flash the system. See “Updating (flashing) BIOS
from a disc” on page 203
2. System board
001-026-XXX
System FLASH data error
1.
Flash the system. See “Updating (flashing) BIOS
from a disc” on page 203
2. System board
001-027-XXX
System Configuration/Setup error
1.
Run Setup
2. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 203
3. System board
001-032-XXX
System Device Controller failure
System board
001-034-XXX
System Device Buffer Allocation failure
1.
Reboot the system
2. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 203
3. Run memory test
4. System board
001-035-XXX
System Device Reset condition detected
System board
001-036-XXX
System Register error
System board
Chapter 7
.
Symptom-to-FRU index
45
Содержание ThinkCentre A63
Страница 1: ...ThinkCentre Hardware Maintenance Manual Machine Types 3317 4013 4478 5043 5237 5393 5526 and 6674 ...
Страница 2: ......
Страница 3: ...ThinkCentre Hardware Maintenance Manual Machine Types 3317 4013 4478 5043 5237 5393 5526 and 6674 ...
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 38: ...32 ThinkCentre Hardware Maintenance Manual ...
Страница 72: ...66 ThinkCentre Hardware Maintenance Manual ...
Страница 212: ...206 ThinkCentre Hardware Maintenance Manual ...
Страница 215: ......
Страница 216: ...Part Number 71Y5807 Printed in USA 1P P N 71Y5807 71Y5807 ...