Table 35. Symptoms and user actions for observable problems (continued)
• If an action step is preceded by
(Trained service technician only)
, that step must be performed only by
a Trained service technician.
Symptom
Action
Power supply - squealing,
scratching, or grinding noise.
1. If the server is running redundant power, pull and replace each power supply,
one at a time, to determine which power supply is causing the noise.
2. If a single power supply is identified as causing the problem, complete the
following steps:
a. Make sure that the power supply causing the noise does not have an
obstruction (cable, cable label, etc).
b. Replace the power supply.
3. If the noise can not be associated with a single power supply, it might be
coming from the cooling fans.
Power supply - Jet or
fast-moving air noise.
Check the IMM event log for events associated with thermals, cooling, and fans.
Power supply - Clicking or
rattling noise.
1. If the server is running redundant power, pull and replace each power supply,
one at a time, to determine which power supply is causing the noise.
2. If a single power supply is identified as causing the problem, complete the
following steps:
a. Make sure that the power supply causing the noise does not have an
obstruction (cable, cable label, etc).
b. Replace the power supply.
3. If the noise can not be associated with a single power supply, it may be coming
from the cooling fans.
Fans - Squealing, scratching,
or grinding noise.
1. This server has redundant hot-swap cooling. Remove and replace each fan
assembly, one at a time, to determine which assembly is causing the noise.
2. If a single fan assembly is identified as causing the problem, complete the
following steps:
a. Make sure that the fan assembly causing the noise does not have an
obstruction (cable, cable label, etc) touching the fan blades during operation.
b. Replace the fan assembly.
3. If the noise can not be associated with a single fan assembly, it might be
coming from the cooling fans in a power supply.
Fans - Jet or fast moving air
noise.
Check the IMM event log for events associated with thermals, cooling, and fans.
Fans - Clicking, or rattling
noise.
1. This server has redundant hot-swap cooling. Remove and replace each fan
assembly, one at a time, to determine which assembly is causing the noise.
a. Make sure that the fan assembly causing the noise does not have an
obstruction (cable, cable label, etc) touching the fan blades during operation.
b. Replace the fan assembly.
2. If the noise can not be associated with a single fan assembly, it might be
coming from the cooling fans in a power supply.
Visible physical damage;
Broken, damaged, or
malfunctioning door, bezel,
cover, or chassis part.
Contact Lenovo Support.
190
Lenovo System x3750 M4 Installation and Service Guide
Содержание System x3750 M4
Страница 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Страница 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Страница 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Страница 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Страница 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 981: ......
Страница 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...