With rack conversion kit:
Width: 423 mm (16.6 in)
Depth: 706 mm (27.8 in)
Height: 218 mm (8.6 in )
Weight fully configured: 44.2 kg (97.4 lb)
Weight minimum configuration: 29.5 kg (65 lb) minimum configuration
The server features the following supported environment:
Design to ASHRAE Class A3, ambient of 36 °C to 40 °C (96.8 °F to 104 °F), with relaxed support:
Supports cloud-like workload with no performance degradation acceptable (Turbo-Off).
Under no circumstance can any combination of worst-case workload and configuration
result in system shutdown or design exposure at 40 °C.
The worst-case workload (like Linpack, Turbo-On) might have performance degradation.
Air temperature:
Server on: 5 - 40 °C (41 to 104 °F); altitude: 0 - 950 m (3,100 ft)
Server on: 5 - 28 °C (41 - 82 °F); altitude: 915 m (3,000 ft) - 3050 m (10,000 ft)
Server off (with standby power): 5 - 45 °C (41 - 113 °F)
Storage: 1 - 60 °C (34 - 140 °F)
Shipping: -40 - 60 °C (-40 - 140 °F)
Humidity: 8 - 85%, Max. Dew Point 24 °C
Electrical:
Models with 1500 W AC power supplies:
200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 8.35 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.10 kVA
Maximum configuration: 1.967 kVA
Models with 900 W AC power supplies:
100 - 127 (nominal) V ac; 50 Hz or 60 Hz; 10.3 A
200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 5.0 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.15 kVA
Maximum configuration: 1.194 kVA
Models with 750 W Platinum AC power supplies:
100 - 127 (nominal) V ac; 50 Hz or 60 Hz; 8.6 A
200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 4.2 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.15 kVA
Maximum configuration: 1.015 kVA
Models with 750 W Titanium AC power supplies:
200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 4.2 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.15 kVA
Maximum configuration: 0.965 kVA
Models with 550 W AC power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 6.5 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 3.3 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.16 kVA
Maximum configuration: 0.732 kVA
BTU output:
Base configuration: 2931 Btu/hr (859 watts)
Maximum configuration: 4043 Btu/hr (1185 watts)
Lenovo System x3500 M5