Replacing the coin-cell battery (also called CMOS battery)
The following notes describe information that you must consider when replacing the coin-cell battery in
the server.
• When replacing the coin-cell battery, you must replace it with a lithium battery of the same type from
the same manufacturer.
• To order replacement batteries, call 1-800-426-7378 within the United States, and 1-800-465-7999 or
1-800-465-6666 within Canada. Outside the U.S. and Canada, call your sales representative or reseller.
• After you replace the system-board battery, you must reconfigure the server and reset the system date
and time.
• To avoid possible danger, read and follow the following safety statement.
Statement 2
CAUTION:
When replacing the lithium battery, use only Part Number 33F8354 or an equivalent type battery
recommended by the manufacturer. If your system has a module containing a lithium battery, replace
it only with the same module type made by the same manufacturer. The battery contains lithium and
can explode if not properly used, handled, or disposed of.
Do not:
• Throw or immerse into water
• Heat to more than 100°C (212°F)
• Repair or disassemble
Dispose of the battery as required by local ordinances or regulations.
To install the replacement coin-cell battery, complete the following steps:
Step 1.
Follow any special handling and installation instructions that come with the replacement battery.
Step 2.
Read the safety information that begins on “Safety” on page v and “Removing and replacing
guidelines” on page 101.
Step 3.
Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 4.
Remove the top cover (see “Removing the top cover” on page 116).
Step 5.
If necessary, lift the riser-card assembly 2 out of the way (see “Removing a riser-card assembly” on
page 143).
Step 6.
Insert the new battery:
192
HX3510-G, HX5510, HX5510-C, HX7510 Installation and Service Guide
Содержание HX3510-G
Страница 1: ...HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide Machine Type 8695 ...
Страница 6: ...iv HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 62: ...50 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 102: ...90 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 112: ...100 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1222: ...1210 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1229: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1217 ...
Страница 1230: ...Taiwan BSMI RoHS declaration 1218 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1238: ...1226 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1239: ......
Страница 1240: ......