Step 16. Reset the CMOS by removing the coin-cell battery (also called CMOS battery). See “Removing
the coin-cell battery (also called CMOS battery)” on page 189.
Step 17. Leave the coin-cell battery out of the server for approximately 5 to 15 minutes.
Step 18. Reinstall the coin-cell battery (see “Replacing the coin-cell battery (also called CMOS battery)” on
Step 19. Reinstall the top cover (see “Replacing the top cover” on page 118).
Step 20. Reconnect the power cord and any cables that you removed.
Step 21. Restart the server. The system begins the power-on self-test (POST).
Step 22. If these recovery efforts fail, contact your service representative for support.
In-band automated boot recovery method
This section details the in-band automated boot recovery method.
Note:
Use this method if the BOARD LED on the light path diagnostics panel is lit and there is a log entry
or
Booting Backup Image
is displayed on the firmware splash screen; otherwise, use the in-band manual
recovery method.
Step 1.
Boot the server to an operating system that is supported by the firmware update package that
you downloaded.
Step 2.
Perform the firmware update by following the instructions that are in the firmware update package
readme file.
Step 3.
Restart the server.
Step 4.
At the firmware splash screen, press F3 when prompted to restore to the primary bank. The
server boots from the primary bank.
Out-of-band method
See the IMM2 documentation (
Integrated Management Module II User's Guide
) at
Automated boot recovery (ABR)
Use this information for Automated boot recovery (ABR).
While the server is starting, if the integrated management module II detects problems with the server
firmware in the primary bank, the server automatically switches to the backup firmware bank and gives
you the opportunity to recover the firmware in the primary bank. For instructions for recovering the UEFI
firmware, see “Recovering the server firmware (UEFI update failure)” on page 86. After you have recovered
the firmware in the primary bank, complete the following steps:
Step 1.
Restart the server.
Step 2.
When the prompt
Press F3 to restore to primary
is displayed, press F3 to start the server from
the primary bank.
Nx-boot failure
Use this information for Nx-boot failure.
88
HX3510-G, HX5510, HX5510-C, HX7510 Installation and Service Guide
Содержание HX3510-G
Страница 1: ...HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide Machine Type 8695 ...
Страница 6: ...iv HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 62: ...50 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 102: ...90 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 112: ...100 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1222: ...1210 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1229: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1217 ...
Страница 1230: ...Taiwan BSMI RoHS declaration 1218 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1238: ...1226 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1239: ......
Страница 1240: ......