background image

Flex System IB6132 2-port FDR InfiniBand Adapter

5

Supported I/O modules

The IB6132 2-port FDR InfiniBand Adapter supports the I/O module listed in the following table. One or 

two compatible switches must be installed in the corresponding I/O bays in the chassis. Installing two 

switches means that both ports of the adapter are enabled. The adapter has a total bandwidth of 56 Gbps. 

That total bandwidth is shared when two switches are installed. To operate at FDR speeds (56 Gbps), you 

must also install the FDR Upgrade license, 90Y3462.

Table 3. I/O modules supported with the IB6132 2-port FDR InfiniBand Adapter 

Description

Part number

Flex System IB6131 InfiniBand Switch

90Y3450

Flex System IB6131 InfiniBand Switch (FDR Upgrade)*

90Y3462

* This license allows the switch to support FDR speeds.

The following table shows the connections between adapters installed in the compute nodes to the switch 

bays in the chassis.

Table 4. Adapter to I/O bay correspondence

I/O adapter slot in the server

Port on the adapter

Corresponding I/O module bay in the chassis

Port 1

Module bay 1

Slot 1

Port 2

Module bay 2

Port 1

Module bay 3

Slot 2

Port 2

Module bay 4

Содержание Flex System IB6132

Страница 1: ...etwork deployment by consolidating clustering communications and management I O and helps provide enhanced performance in virtualized server environments Figure 1 shows the Flex System IB6132 2 port FDR InfiniBand Adapter Figure 1 Flex System IB6132 2 port FDR InfiniBand Adapter Did you know Mellanox InfiniBand adapters deliver industry leading bandwidth with ultra low sub microsecond latency for ...

Страница 2: ... With the ConnectX 3 based adapter highly compute intensive tasks running on hundreds or thousands of multiprocessor nodes such as climate research molecular modeling and physical simulations can share data and synchronize faster resulting in shorter run times High frequency transaction applications are able to access trading information more quickly making sure that the trading servers are able t...

Страница 3: ...0 Gb s per lane Fourteen Data Rate FDR 56 Gb s 14 Gb s per lane PCI Express 3 0 x8 host interface up to 8 gigatransfers per second GT s bandwidth CPU off load of transport operations CORE Direct application off load GPUDirect application off load End to end QoS and congestion control Hardware based I O virtualization Transmission Control Protocol TCP User Datagram Protocol UDP Internet Protocol IP...

Страница 4: ...rt FDR InfiniBand Adapter 90Y3454 Y N Y Y Y Y N Y N N N N See ServerProven at the following web address for the latest information about the expansion cards that are supported by each blade server type http ibm com servers eserver serverproven compat us I O adapter cards are installed in the slot in supported servers such as the x240 as highlighted in the following figure Figure 2 Location of the ...

Страница 5: ...6 Gbps you must also install the FDR Upgrade license 90Y3462 Table 3 I O modules supported with the IB6132 2 port FDR InfiniBand Adapter Description Part number Flex System IB6131 InfiniBand Switch 90Y3450 Flex System IB6131 InfiniBand Switch FDR Upgrade 90Y3462 This license allows the switch to support FDR speeds The following table shows the connections between adapters installed in the compute ...

Страница 6: ... the following 64 bit operating systems Microsoft Windows Server 2008 R2 Microsoft Windows Server 2008 Datacenter x64 Edition Microsoft Windows Server 2008 Enterprise x64 Edition Microsoft Windows Server 2008 Standard x64 Edition Microsoft Windows Server 2008 Web x64 Edition Microsoft Windows Server 2012 Microsoft Windows Server 2012 R2 Red Hat Enterprise Linux 5 Server x64 Edition Red Hat Enterpr...

Страница 7: ...ZS CISPR 22 2006 Class A IEC 60950 1 CB Certificate and CB Test Report Taiwan BSMI CNS13438 Class A Korea KN22 Class A KN24 Russia GOST ME01 IEC 60950 1 GOST R 51318 22 99 GOST R 51318 24 99 GOST R 51317 3 2 2006 GOST R 51317 3 3 99 IEC 60950 1 CB Certificate and CB Test Report CE Mark EN55022 Class A EN60950 1 EN55024 EN61000 3 2 and EN61000 3 3 CISPR 22 Class A Physical specifications The dimens...

Страница 8: ...parts that are used in the configuration This configuration includes the FDR upgrade license for the IB6131 switch as well as the FDR cables Table 5 Components used when connecting the IB6132 2 port FDR InfiniBand Adapter to the IB6131 InfiniBand Switches Part number machine type Description Quantity 8737 Flex System x240 Compute Node 1 to 14 90Y3454 IB6132 2 port FDR InfiniBand Adapter 1 per serv...

Страница 9: ...xsys information Flex System Interoperability Guide http www redbooks ibm com fsig Flex System Products and Technology by Lenovo SG24 8255 http www redbooks ibm com abstracts sg248255 html Open IBM Configurator for e business e config http ibm com services econfig System x and Cluster Solutions configurator x config http ibm com products hardware configurator americas bhui asit System x Configurat...

Страница 10: ...ions of the publication Lenovo may make improvements and or changes in the product s and or the program s described in this publication at any time without notice The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or ...

Страница 11: ...with the appropriate symbol or indicating US registered or common law trademarks owned by Lenovo at the time this information was published Such trademarks may also be registered or common law trademarks in other countries A current list of Lenovo trademarks is available on the Web at http www lenovo com legal copytrade html The following terms are trademarks of Lenovo in the United States other c...

Отзывы: