If necessary, obtain the IP address of the management module from your
system administrator. The management-module window opens.
Note:
The
User ID
and
Password
fields are case-sensitive. Type your
information in uppercase letters only. To maintain system security,
change your password after you log on for the first time. The default
User ID is
USERID
, and the default password is
PASSW0RD
(where the sixth
character is the number zero, not the letter O).
2.
From the
I/O Module Tasks
menu, click
Configuration
.
3.
In the
I/O Module Configuration
area, click the bay number that corresponds
to the location of the switch that you installed.
4.
In the
IP address
field in the
New Static IP Configuration
area, type the new
TCP/IP address of the switch; then, click
Save
.
Note:
The management module does not check for invalid IP addresses.
5.
Click
Advanced Configuration
. You can now start a Web session or a Telnet
session.
The Web interface and the Telnet program provide different ways to access the
same internal-switching firmware and configure it.
v
If your system application requires that you use the Web interface program, see
“Configuring the switch through the switch browser-based interface” on page 21
for additional information.
v
If your system application requires that you use the Telnet program, see
“Configuring the switch through the Telnet interface” on page 20 for additional
information.
Enabling management through external ports
To access and manage the switch through external interfaces, you must enable the
external ports and the ability to manage the switch through them. Use the
information in the following table to configure your ports.
External management
External ports
Description
Disabled
Disabled
The switch must be managed
through the management
module. No traffic is allowed on
external ports.
Disabled
Enabled
The switch must be managed
through the management
module. Data traffic is allowed
on external ports.
Enabled
Disabled
The switch can be managed
through the management
module or a blade server. No
traffic is allowed on external
ports.
Enabled
Enabled
The switch can be managed
through the management
module, a blade server, or a
management station that is
connected through an external
port. Data traffic is allowed on
external ports.
Chapter 2. Installing the switch
19
Содержание Flex System EN2092
Страница 1: ...Flex System EN2092 1Gb Ethernet Scalable Switch User s Guide ...
Страница 2: ......
Страница 3: ...Flex System EN2092 1Gb Ethernet Scalable Switch User s Guide ...
Страница 7: ...Safety Safety statements Lenovo 2015 Portions IBM Corp 2013 v ...
Страница 8: ...vi 1Gb Ethernet Scalable Switch User s Guide ...
Страница 9: ...Safety vii ...
Страница 14: ...4 1Gb Ethernet Scalable Switch User s Guide ...
Страница 40: ...30 1Gb Ethernet Scalable Switch User s Guide ...
Страница 52: ...42 1Gb Ethernet Scalable Switch User s Guide ...
Страница 55: ......
Страница 56: ...Part Number 00WA358 Printed in USA 1P P N 00WA358 ...