background image

Lenovo System x3550 M5 (E5-2600 v3)

Product Guide

Designed in a compact, versatile 1U two-socket rack server, the Lenovo System x3550 M5 rack server

fuels almost any workload from infrastructure to high-performance computing (HPC) to cloud or big data

with leadership security, efficiency, and reliability. Integrated with up to two Intel Xeon processors of the

E5-2600 v3 product family with faster, energy-efficient TruDDR4 Memory, the x3550 M5 delivers

exceptional performance. Storage can include up to 12 drives in an impressive selection of sizes and types.

Suggested use: Database, virtualization and cloud computing, infrastructure security, systems

management, enterprise applications, collaboration/email, streaming media, web, and HPC.

The following figure shows the System x3550 M5.

Figure 1. Lenovo System x3550 M5

Did you know?

The x3550 M5 incorporates energy smart features for minimized costs and efficient performance. Dual fan

zones support operation in up to 40°C environments. 80 PLUS Titanium power supply units (PSUs) can

deliver 96% efficiency at 50% load.

The x3550 M5 has outstanding memory performance that is achieved by supporting two-RDIMM-per-

channel configurations at speeds up to 12% faster than the Intel specification, while still maintaining world-

class reliability.

System x® servers achieved the highest reliability of any x86 servers (ITIC 2015-2016 Global Server

Hardware, Server OS Reliability Survey:

http://www.lenovo.com/images/products/system-x/pdfs/white-papers/itic_2015_reliability_wp.pdf

The x3550 M5 integrates leadership security and reliability. System x Trusted Platform Assurance, an

exclusive set of System x features and practices, establishes a foolproof security foundation for your

workloads. Enterprise-class data protection is provided with optional self-encrypting drives and simple,

centralized key management through IBM Security Key Lifecycle Management. Diagnostic tools facilitate

reduced downtime and costs.

Lenovo System x3550 M5 (E5-2600 v3)

1

Содержание E5-2600 v3

Страница 1: ...sts and efficient performance Dual fan zones support operation in up to 40 C environments 80 PLUS Titanium power supply units PSUs can deliver 96 efficiency at 50 load The x3550 M5 has outstanding memory performance that is achieved by supporting two RDIMM per channel configurations at speeds up to 12 faster than the Intel specification while still maintaining world class reliability System x serv...

Страница 2: ...yper Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core up to two threads per core Intel Virtualization Technology integrates hardware level virtualization hooks that allow operating system vendors to better utilize the hardware for virtualization workloads Intel Advanced Vector Extensions 2 0 AVX 2 0 enable acc...

Страница 3: ...s simplify local and remote management of the x3550 M5 and deliver enterprise class data protection The server includes an Integrated Management Module II IMM2 to monitor server availability and perform remote management An integrated industry standard Unified Extensible Firmware Interface UEFI enables improved setup configuration and updates and simplifies error handling XClarity Administrator of...

Страница 4: ...d telecommunication environments Low voltage 1 2 V DDR4 memory DIMMs offer energy efficiency compared to 1 35 V and 1 5 V DDR3 DIMMs The server uses hexagonal ventilation holes a part of Calibrated Vectored Cooling technology Hexagonal holes can be grouped more densely than round holes providing more efficient airflow through the system Intel Node Manager provide advanced data center power notific...

Страница 5: ...peeds or 8 cores up to 3 2 GHz core speeds or 6 cores up to 3 4 GHz core speeds or 4 cores up to 3 5 GHz core speeds Two QPI links up to 9 6 GT s each Up to 2133 MHz memory speed Up to 45 MB L3 cache Chipset Intel C612 Memory Up to 24 DIMM sockets 12 DIMMs per processor RDIMMs and LRDIMMs Load Reduced DIMMs are supported Memory types cannot be intermixed Memory speed up to 2133 MHz Memory maximums...

Страница 6: ...ength PCIe 3 0 x16 slot requires the second processor to be installed not present if the HDD Rear Kit is installed Slot 3 PCIe 3 0 x16 or PCIe 3 0 x8 low profile half length Slot 4 PCIe 3 0 x8 dedicated for an internal RAID controller Ports Front 1x USB 2 0 8x 2 5 drive bay models or 2x USB 2 0 l 4x 3 5 and 10x 2 5 drive bay models 1x USB 3 0 and 1x DB 15 video Rear 2x USB 3 0 1x USB 2 0 1x DB 15 ...

Страница 7: ... and two for models with two power supplies Note Cable Management Arm CMA is not included See the Rack installation section for ordering information Standard models The following table lists the standard models of the x3550 M5 Table 2 Standard models Model number Intel Xeon processor 2 maximum Memory RDIMMs RAID Drive bays Drives NIC I O slots std max Optical drive Power supply std max Models anno...

Страница 8: ...emory speed and TDP For these models the standard DIMM is rated at 2133 MHz but operates at a lower speed to match the processor memory speed Actual memory speed maximums depend on several factors as described in Memory options Express and TopSeller models The following table lists the Express and TopSeller models of the x3550 M5 Table 3 Express and TopSeller models Model number Intel Xeon process...

Страница 9: ...HS 2 5463K3G 1x E5 2620 v3 6C 2 4GHz 15MB 1866MHz 85W 1x 16GB 2133MHz M5210 4x 2 5 HS 8 Open bay 4x GbE 2 4 Optional 1x 550 W HS 2 5463K4G 1x E5 2620 v3 6C 2 4GHz 15MB 1866MHz 85W 1x 16GB 2133MHz M5210 4x 2 5 HS 8 Open bay 4x GbE 2 4 Optional 1x 750 W HS 2 5463K5G 1x E5 2630 v3 8C 2 4GHz 20MB 1866MHz 85W 1x 16GB 2133MHz M5210 4x 2 5 HS 8 Open bay 4x GbE 2 4 Optional 1x 750 W HS 2 5463K6G 1x E5 264...

Страница 10: ... SS 8 Open bay 4x GbE 4 4 Multi burner 2x 550 W HS 2 5463EOU 1x E5 2620 v3 6C 2 4GHz 15MB 1866MHz 85W 1x 8GB 2133MHz M5210 1GB Flash 4x 3 5 SS 4 Open bay 4x GbE 4 4 Multi burner 2x 550 W HS 2 5463EPU 1x E5 2640 v3 8C 2 6GHz 20MB 1866MHz 90W 2x 16GB 2133MHz M5210 1GB Flash 4x 2 5 HS 8 Open bay 4x GbE 4 4 Multi burner 2x 550 W HS 2 5463EQU 2x E5 2680 v3 12C 2 5GHz 30MB 2133MHz 120W 2x 16GB 2133MHz M...

Страница 11: ...ver models have each processor standard If there is no corresponding where used model for a particular processor this processor is only available through Configure to order CTO The processor part numbers include a CPU a heatsink and two system fans Table 4 Processor options Part number Feature codes Description Standard models where used 00KA070 A5BF A5BV Intel Xeon Processor E5 2603 v3 6C 1 6GHz ...

Страница 12: ...ormance and reliability TruDDR4 Memory will have a unique signature programmed into the DIMM which will enable System x servers to verify whether the memory installed is qualified supported Because TruDDR4 Memory is authenticated certain extended memory performance features can be enabled to extend performance over industry standards From a service and support standpoint System x memory automatica...

Страница 13: ... per channel 1600 MHz 1600 MHz 1866 MHz 1866 MHz The maximum quantity that is supported is shown for two processors installed The following table lists memory options available for the x3550 M5 server Table 6 Memory options Part number Feature code Description Maximum supported Standard models where used RDIMMs 2133 MHz 46W0784 A5B6 4GB TruDDR4 Memory 1Rx8 1 2V PC4 17000 CL15 2133MHz LP RDIMM 24 1...

Страница 14: ...l drive The following table shows the internal storage options available for the x3550 M5 server Table 7 Internal storage options Part number Feature code Description Maximum supported Standard models where used Base drive kits None A59W System x3550 M5 4x 2 5 HS HDD Kit 1 62x C2x D2x F2x H2x J2x L2x M2x N2x P2x Q2x None A5A4 System x3550 M5 4x 3 5 HS HDD Kit 1 C4x None A5A0 System x3550 M5 10x 2 ...

Страница 15: ...1x System x3550 M5 4x 2 5 HS HDD Kit PLUS FC A59X Field upgrade for the 4 drive bay model 1x System x3550 M5 4x 2 5 HS HDD Kit PLUS PN 00KA055 10 1x M1215 or 1x M5210 or 1x N2215 Factory installed 1x System x3550 M5 10x 2 5 HS HDD Kit FC A5A0 12 1x M1215 or 1x M5210 or 1x N2215 Factory installed 1x System x3550 M5 10x 2 5 HS HDD Kit FC A5A0 and 1x System x3550 M5 2x 2 5 HS HDD Rear Kit FC A5A2 Fie...

Страница 16: ...x 46C9114 A45W ServeRAID M1215 SAS SATA Controller 1 A2x B2x C2x C4x 47C8675 A3YY N2215 SAS SATA HBA 1 Hardware upgrades for the M5210 per one controller 47C8656 A3Z0 ServeRAID M5200 Series 1GB Cache RAID 5 Upgrade 1 47C8660 A3Z1 ServeRAID M5200 Series 1GB Flash RAID 5 Upgrade 1 D2x F2x G2x H2x 47C8664 A3Z2 ServeRAID M5200 Series 2GB Flash RAID 5 Upgrade 1 62x J2x N2x P2x Q2x 47C8668 A3Z3 ServeRAI...

Страница 17: ...A SAS SATA SAS SATA SAS SATA Drive type HDD HDD SSD SED HDD SSD SED HDD SSD Drive form factor SFF LFF SFF LFF SFF LFF SFF LFF Hot swap drives No Yes Yes Yes Max devices 8 32 RAID 64 JBOD 240 1024 RAID levels None 0 1 10 Optional 5 50 00AE930 0 1 10 Optional 5 50 RAID 5 FoD 47C8708 or cache upgrades Optional 6 60 47C8706 None JBOD mode Yes Yes Yes without cache Yes Cache None None 1 GB no backup 47...

Страница 18: ...drive options for internal storage of the x3550 M5 server For a list of compatible drive options that includes withdrawn drives that are no longer available for ordering refer to the Storage devices section on the x3550 M5 ServerProven compatibility page http www lenovo com us en serverproven xseries 5463 shtml Storage Table 12 Internal drive options 2 5 inch hot swap drives Part number Feature co...

Страница 19: ...B 12G SAS 2 5 MLC G3HS Enterprise SSD 12 00FN409 AS7J 1 6TB 12G SAS 2 5 MLC G3HS Enterprise SSD 12 2 5 inch hot swap SSDs Enterprise Mainstream 12 Gbps SAS 00YC460 AT9M 400GB Enterprise Mainstream 12Gb SAS G3HS 2 5 SSD 12 00YC465 AT9N 800GB Enterprise Mainstream 12Gb SAS G3HS 2 5 SSD 12 00YC470 AT9P 1 6TB Enterprise Mainstream 12Gb SAS G3HS 2 5 SSD 12 2 5 inch hot swap SSDs Enterprise 6 Gbps SAS 0...

Страница 20: ...D 8 00NA622 ASLD 1TB 7 2K 6Gbps NL SATA 2 5 G3SS HDD 8 00NA536 AT82 2TB 7 2K 6Gbps NL SATA 2 5 G3SS 512e HDD 8 Table 14 Internal drive options 3 5 inch hot swap drives Part number Feature code Description Maximum supported 3 5 inch hot swap HDDs 12Gbps SAS 00WG675 AT87 300GB 15K 12Gbps SAS 3 5 G2HS HDD 4 00WG680 AT88 600GB 15K 12Gbps SAS 3 5 G2HS HDD 4 3 5 inch hot swap HDDs 12 Gbps NL SAS 00FN188...

Страница 21: ...A HS 3 5 SSD 4 00WG775 AT98 Intel S3510 240GB Enterprise Entry SATA HS 3 5 SSD 4 00WG780 AT99 Intel S3510 480GB Enterprise Entry SATA HS 3 5 SSD 4 00YC420 AT8Y 960GB Enterprise Entry SATA HS 3 5 SSD 4 Part number Feature code Description Maximum supported Table 15 Internal drive options 3 5 inch simple swap drives Part number Feature code Description Maximum supported 3 5 inch simple swap HDDs 6 G...

Страница 22: ...mm SATA Multi Burner 1 Ultraslim 9 5mm SATA DVD ROM part number 00AM066 supports the following media and speeds for reading CD ROM 24X CD DA DAE 24X CD R 24X CD RW 24X DVD ROM 8X DVD R 8X DVD R 8X DVD R DL 6X DVD R DL 8X DVD RW 8X DVD RW 8X DVD RAM 4 7 GB 5X Ultraslim 9 5mm SATA Multi Burner part number 00AM067 supports the same media and speeds for reading as DVD ROM part number 00AM066 This driv...

Страница 23: ... dedicated for an internal RAID controller The locations of the PCIe slots are shown in the following figure Figure 6 PCIe slot locations Riser 1 supplies slot 1 and Riser 2 supplies slots 2 and 3 The slots that are available for use depend on the number of riser cards that are installed and whether the second processor is installed One or two processors and no riser cards Slot 4 is available for ...

Страница 24: ...5 PCIe Riser 2 1 2 CPU LP x16 CPU1 LP x16 CPU0 1 Only available via CTO or special bid Configuration notes The 1 CPU Riser 2 options feature codes A5AC and A5AE are supported only in configurations with one processor If two processors are selected these options cannot be used If the FHHL x16 Riser 2 option feature code A5AD is selected the x16 Riser 1 option feature code A5AG cannot be used If bot...

Страница 25: ...em x3550 M5 Thermal Kit 1 00KA161 A5AN COM Port Bracket 1 Network adapters The x3550 M5 supports four integrated Gigabit Ethernet ports The integrated network interface controller NIC has the following features A Broadcom BCM5719 chip Four Gigabit Ethernet ports NIC Teaming load balancing and failover Ethernet features Compliant with 1 Gb Ethernet IEEE 802 3 802 3u and 802 3ab PHY specifications I...

Страница 26: ...ts 00D9550 A3PN Mellanox ConnectX 3 40GbE FDR IB VPI Adapter 3 10 Gb Ethernet PCIe Low Profile supported in Low Profile and Half High PCIe slots 44T1370 A5GZ Broadcom NetXtreme 2x10GbE BaseT Adapter 3 94Y5180 A4Z6 Broadcom NetXtreme Dual Port 10GbE SFP Adapter 3 00JY820 A5UT Emulex VFA5 2x10 GbE SFP PCIe Adapter 3 00AG570 AT7S Emulex VFA5 2 2x10 GbE SFP PCIe Adapter 3 00JY824 A5UV Emulex VFA5 FCoE...

Страница 27: ...umber of transceivers or cables that are supported per adapter equals the quantity of the adapter ports All adapter ports must have the same type of transceiver or DAC cable selected For more information see the list of Product Guides in the Ethernet adapters category https lenovopress com servers options ethernet SAS adapters for external storage The following table lists SAS RAID controllers and...

Страница 28: ...l PN 47C8710 None None SSD Caching CacheCade Pro 2 0 Optional PN 47C8712 None None For more information see the following Lenovo Press Product Guides ServeRAID M5225 2GB http lenovopress com tips1258 N2225 and N2226 SAS SATA HBAs http lenovopress com tips1175 Fibre Channel host bus adapters The following table lists Fibre Channel HBAs supported by the x3550 M5 server Table 22 Fibre Channel HBAs Pa...

Страница 29: ... 00JY004 ARYS 5200GB Enterprise io3 Flash Adapter FH 1 Enterprise Value 00AE983 ARYK 1250GB Enterprise Value io3 Flash Adapter LP 3 00AE986 ARYL 1600GB Enterprise Value io3 Flash Adapter LP 3 00AE989 ARYM 3200GB Enterprise Value io3 Flash Adapter LP 3 00AE992 ARYN 6400GB Enterprise Value io3 Flash Adapter FH 1 Supported only in the PCIe slot 2 and requires the FHHL x16 Riser Card 2 feature code A5...

Страница 30: ... 00KA094 A5AX System x 550W High Efficiency Platinum AC Power Supply 2 A2x B2x C2x C4x D2x F2x G2x H2x 00KA096 A5AY System x 750W High Efficiency Platinum AC Power Supply 2 62x J2x N2x P2x Q2x 00KA097 A5AZ System x 750W High Efficiency Titanium AC Power Supply 200 240V 2 L2x 00KA098 A5B0 System x 900W High Efficiency Platinum AC Power Supply 2 M2x 00MV212 ASPR System x 900W High Efficiency 48 V DC...

Страница 31: ...cord 39Y7925 6219 Korea 12A 250V C13 to KETI 2 8m line cord 39Y7922 6214 South Africa 10A 250V C13 to SABS 164 2 8m line cord 39Y7919 6216 Switzerland 10A 250V C13 to SEV 1011 S24507 2 8m line cord 00CG265 A53E Taiwan 10A 250V C13 to CNS 10917 3 2 8m line cord 00CG267 A53F Taiwan 15A 125V C13 to CNS 10917 3 2 8m line cord 39Y7923 6215 United Kingdom 10A 250V C13 to BS 1363 A 2 8m line cord 39Y7931...

Страница 32: ...y CTO only Systems management The server contains Integrated Management Module II IMM2 1 which provides advanced service processor control monitoring and an alerting function If an environmental condition exceeds a threshold or if a system component fails the IMM lights LEDs to help you diagnose the problem records the error in the event log and alerts you to the problem Optionally the IMM also pr...

Страница 33: ...3550 M5 Express models come standard with the Advanced LCD Light path Kit E1G E2G E3G E4G E5J E6J E7J EAU EBU ECU EDU EEU EFU EHM EJM EKM ELM ENU EPU EQU ERU and ESU The following x3550 M5 TopSeller models come standard with the Advanced LCD Light path Kit NAU NDU NDG NMU NJU NEU NEG NNU NFU NHU NPU NKU NKG NQU NRU NSU E8U E9U ETU and EUU The following x3550 M5 TopSeller models come standard witho...

Страница 34: ...ing operating systems Microsoft Microsoft Windows Server 2012 R2 Microsoft Windows Server 2012 Microsoft Windows Server 2008 R2 SP1 Red Hat Red Hat Enterprise Linux 7 2 Red Hat Enterprise Linux 7 1 Red Hat Enterprise Linux 7 Red Hat Enterprise Linux 6 7 Server x64 Edition Red Hat Enterprise Linux 6 6 Server x64 Edition Red Hat Enterprise Linux 6 5 Server x64 Edition SUSE SUSE Linux Enterprise Serv...

Страница 35: ... ambient of 40 C 104 F with relaxed support Supports cloud like workload with no performance degradation acceptable Turbo Off Under no circumstance can any combination of worst case workload and configuration result in system shutdown or design exposure at 40 C Electrical Models with 1500 W AC Platinum power supplies 200 240 nominal V ac 50 Hz or 60 Hz 8 35 A Input kilovolt amperes kVA approximate...

Страница 36: ...the client s location for equipment service 24x7x2 hour A service technician is scheduled to arrive at the client s location within two hours after remote problem determination is completed Lenovo provides service around the clock every day including Lenovo holidays 24x7x4 hour A service technician is scheduled to arrive at the client s location within four hours after remote problem determination...

Страница 37: ...ol regardless of the number of hard drives that are installed in your Lenovo server In the unlikely event of a hard drive failure you retain possession of your hard drive while Lenovo replaces the failed drive part Your data stays safely on your premises in your hands The Hard Drive Retention service can be purchased in convenient bundles with our warranty upgrades and extensions Microcode Support...

Страница 38: ...Class A TUV GS EN60950 1 IEC60950 1 EK1 ITB2000 RoHS Directive External drive enclosures The following table lists the external drive enclosures that are offered by Lenovo that can be used in System x3550 M5 solutions Table 32 External drive enclosures Part number Description 64111B1 Lenovo Storage E1012 LFF Disk Expansion Single SAS IO Module Rail Kit 9x5 NBD 64111B2 Lenovo Storage E1012 LFF Disk...

Страница 39: ...FF Chassis FC iSCSI Single Controller Rack Kit 9x5NBD 64116B2 Lenovo Storage S3200 LFF Chassis FC iSCSI Dual Controller Rack Kit 9x5NBD 64113B3 Lenovo Storage S3200 SFF Chassis SAS Single Controller Rack Kit 9x5NBD 64113B4 Lenovo Storage S3200 SFF Chassis SAS Dual Controller Rack Kit 9x5NBD 64116B3 Lenovo Storage S3200 SFF Chassis FC iSCSI Single Controller Rack Kit 9x5NBD 64116B4 Lenovo Storage S...

Страница 40: ... External tape backup libraries 61732UL IBM TS3100 Tape Library Model L2U 61734UL IBM TS3200 Tape Library Model L4U Fibre Channel backup drives for TS3100 and TS3200 Tape Libraries 00NA107 6173 LTO Ultrium 5 Fibre Channel Drive 00NA113 6173 LTO Ultrium 5 Half High Fibre Drive Sled 00NA115 6173 LTO Ultrium 6 Fibre Channel Drive 00NA119 6173 LTO Ultrium 6 Half High Fibre Drive Sled 00WF765 6173 LTO ...

Страница 41: ...roduct Guides in the Top of rack switches category http lenovopress com servers options switches Fibre Channel SAN switches The following table lists the Fibre Channel SAN switches that are offered by Lenovo that can be used in System x3550 M5 solutions Table 36 Fibre Channel SAN switches Part number Description 8 Gb Fibre Channel 3873AR1 Brocade 300 FC SAN Switch 3873AR3 Lenovo B300 8 ports activ...

Страница 42: ...VM switch and console options Part number Description Consoles 17238BX 1U 18 5 Standard Console without keyboard Console keyboards 46W6712 Keyboard w Int Pointing Device USB US Eng 103P RoHS v2 46W6713 Keyboard w Int Pointing Device USB Arabic 253 RoHS v2 46W6714 Keyboard w Int Pointing Device USB Belg UK 120 RoHS v2 46W6715 Keyboard w Int Pointing Device USB Chinese US 467 RoHS v2 46W6716 Keyboar...

Страница 43: ...RoHS v2 46W6737 Keyboard w Int Pointing Device USB Thai 191 RoHS v2 46W6738 Keyboard w Int Pointing Device USB Turkish 179 RoHS v2 46W6739 Keyboard w Int Pointing Device USB UK Eng 166 RoHS v2 46W6740 Keyboard w Int Pointing Device USB US Euro 103P RoHS v2 46W6741 Keyboard w Int Pointing Device USB Slovenian 234 RoHS v2 Console switches 1754D2X Global 4x2x32 Console Manager GCM32 1754D1X Global 2x...

Страница 44: ... C13 outlets 39M2816 DPI C13 Enterprise PDU without line cord 39Y8941 DPI Single Phase C13 Enterprise PDU without line cord C19 Enterprise PDUs 6x IEC 320 C19 outlets 39Y8948 DPI Single Phase C19 Enterprise PDU without line cord 39Y8923 DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P G 208 V fixed line cord Front end PDUs 3x IEC 320 C19 outlets 39Y8938 DPI 30amp 125V Front end PDU with NEMA L5 ...

Страница 45: ...ered by Lenovo that can be used in System x3550 M5 solutions Table 40 Uninterruptible power supply units Part number Description 55941AX RT1 5kVA 2U Rack or Tower UPS 100 125VAC 55941KX RT1 5kVA 2U Rack or Tower UPS 200 240VAC 55942AX RT2 2kVA 2U Rack or Tower UPS 100 125VAC 55942KX RT2 2kVA 2U Rack or Tower UPS 200 240VAC 55943AX RT3kVA 2U Rack or Tower UPS 100 125VAC 55943KX RT3kVA 2U Rack or To...

Страница 46: ...ervices to ensure these complex transactions are serviced properly As a premier client you have a dedicated finance specialist who manages your account through its life from first invoice through asset return or purchase This specialist develops an in depth understanding of your invoice and payment requirements For you this dedication provides a high quality easy and positive financing experience ...

Страница 47: ...Related product families Product families related to this document are the following 2 Socket Rack Servers Lenovo System x3550 M5 E5 2600 v3 47 ...

Страница 48: ...nt are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third partie...

Страница 49: ...ler ServerProven System x RackSwitch ServeRAID ToolsCenter TruDDR4 The following terms are trademarks of other companies Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds in the United States other countries or both Microsoft and Windows are trademarks of Microsoft Co...

Отзывы: