background image

System x3630 M4 (E5-2400)

Product Guide

The System x3630 M4 server offers a cost-effective high-capacity storage solution with exceptional

energy-smart design, leadership virtualization, and powerful systems management. It supports up to two

eight-core Intel Xeon processors and high-density memory designs with twelve DDR3 DIMM slots. This 2U

server consolidates storage and server into one system, offers easy management, and saves floor space

and power consumption, costing less money than traditional enterprise offerings. Designed with

redundancy, flexible subsystems, and a wider range of configuration options, the x3630 M4 also offers an

innovative Feature on Demand (FoD) design for an easier upgrade path.

Suggested use: Collaboration/email applications, light databases, virtualization/cloud, virtual desktops,

web serving, and virtual storage.

The following figure shows the System x3630 M4.

Figure 1. The System x3630 M4

Did you know?

The System x3630 M4 server is designed to provide exceptional value and flexibility to meet general

business or storage-intensive requirements with up to 56 TB of storage space in a dense 2U form factor

and 80 PLUS Platinum certified power supplies. The flexible onboard Ethernet solution provides two

standard integrated Gigabit Ethernet ports and two additional integrated Gigabit Ethernet ports with an

optional software FoD upgrade without needing to buy additional hardware. Comprehensive systems

management tools with the next-generation Integrated Management Module II (IMM2) make it easy to

deploy, integrate, service, and manage.

System x3630 M4 (E5-2400)

1

Click here to check for updates

Содержание E5-2400

Страница 1: ...ested use Collaboration email applications light databases virtualization cloud virtual desktops web serving and virtual storage The following figure shows the System x3630 M4 Figure 1 The System x3630 M4 Did you know The System x3630 M4 server is designed to provide exceptional value and flexibility to meet general business or storage intensive requirements with up to 56 TB of storage space in a ...

Страница 2: ...1600 MHz to help maximize system performance The server offers up to four integrated Gigabit Ethernet ports with convenient Feature on Demand upgrade process that does not require the purchasing of an additional hardware The server offers PCI Express 3 0 I O expansion capabilities that improve the theoretical maximum bandwidth by almost 100 8 GTps per link using 128b 130b encoding compared to the ...

Страница 3: ...s faster and stronger encryption Intel Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system Intel Trusted Execution Technology provides enhanced security through hardware based resistance to malicious software attacks allowing an application to run in its own isolated space protected from all other ...

Страница 4: ...ver with eight 3 5 inch drive bays Figure 2 Front view of the System x3630 M4 with eight drive bays The following figure shows the front of the server with twelve 3 5 inch drive bays Figure 3 Front view of the System x3630 M4 with twelve drive bays System x3630 M4 E5 2400 4 ...

Страница 5: ...onal rear HDD cage upgrade Figure 4 Rear view of the System x3630 M4 without the rear HDD cage The following shows the rear of the server with the optional rear HDD cage upgrade Figure 5 Rear view of the System x3630 M4 with the rear HDD cage System x3630 M4 E5 2400 5 ...

Страница 6: ...The following figure shows the locations of key components inside the server Figure 6 Inside view of the System x3630 M4 System x3630 M4 E5 2400 6 ...

Страница 7: ...o 32 TB with 4 TB 3 5 inch SATA SS HDDs or up to 11 2 TB with 800 GB 3 5 inch SATA HS SSDs An intermix of SAS SATA is supported RAID support RAID 0 and 1 with C105 RAID 0 1 and 10 with M1115 or M5110 Upgrades to RAID 5 and 50 are available for M1115 Upgrades to RAID 5 and 50 are available for M5110 zero cache 512 MB battery backed cache 512 MB or 1 GB flash backed cache Upgrade to RAID 6 or 60 is ...

Страница 8: ...atic Server Restart IBM Systems Director and IBM Systems Director Active Energy Manager and ServerGuide Optional IMM Advanced FoD Upgrade for remote presence graphics keyboard and mouse and virtual media Security features Power on password administrator s password and Trusted Platform Module TPM Video Matrox G200eR2 with 16 MB memory integrated into the IMM2 Maximum resolution is 1600x1200 at 75 H...

Страница 9: ...440 6C 2 4GHz 15MB 1333MHz 95W 1x 4GB 1333MHz M5110 512MB f 12x 3 5 HS 14 Open bay 2x GbE 4 5 5 None 1x 750W HS 2 7158F4x 1x E5 2440 6C 2 4GHz 15MB 1333MHz 95W 1x 4GB 1333MHz M5110 512MB f 8x 3 5 HS 8 Open bay 2x GbE 4 5 5 Optional 1x 550W HS 2 7158G2x 1x E5 2450 8C 2 1GHz 20MB 1600MHz 95W 1x 4GB 1333MHz M5110 1GB f 8x 3 5 HS 8 Open bay 2x GbE 4 5 5 Optional 1x 550W HS 2 7158H2x 1x E5 2470 8C 2 3G...

Страница 10: ...G 1x E5 2407 4C 2 2GHz 10MB 1066MHz 80W 1x 4GB 1333MHz M1115 8x 3 5 HS 8 Open bay 2x GbE 4 5 5 Multi burner 1x 550W HS 2 7158E3G 1x E5 2430 6C 2 2GHz 15MB 1333MHz 95W 1x 8GB 1333MHz M5110 512MB f 12x 3 5 HS 14 2x 500GB 7 2K SATA 2x GbE 4 5 5 None 1x 750W HS 2 7158E4G 1x E5 2420 6C 1 9GHz 15MB 1333MHz 95W 1x 8GB 1333MHz M5110 8x 3 5 HS 8 1x 500GB 7 2K SATA 2x GbE 4 5 5 Multi burner 1x 550W HS 2 Uni...

Страница 11: ...e Intel Pentium Processor 1403 2C 2 6GHz 5MB cache 1066MHz 80W None Intel Pentium Processor 1407 2C 2 8GHz 5MB cache 1066MHz 80W None Intel Xeon Processor E5 1410 4C 2 8GHz 10MB Cache 1333MHz 80W These processors only support single processor configurations and are available only through CTO or special bid Memory options Lenovo DDR3 memory is compatibility tested and tuned for optimal System x per...

Страница 12: ...l memory mirroring and memory rank sparing modes are mutually exclusive Only one operational memory mode can be enabled on a server and it is a system wide setting The following table shows the characteristics of the supported DIMMs Table cells highlighted with a gray background indicate when the combination of DIMM voltage and the number of DIMMs per channel still allows the DIMMs to operate at a...

Страница 13: ... Table 6 Memory options Part number Feature code Description Maximum supported Standard models where used UDIMMs 49Y1404 8648 4GB 1x4GB 2Rx8 1 35V PC3L 10600 CL9 ECC 1333MHz LP UDIMM 12 6 per processor RDIMMs 49Y1405 8940 2GB 1x2GB 1Rx8 1 35V PC3L 10600 CL9 ECC DDR3 1333MHz LP RDIMM 12 6 per processor 49Y1406 8941 4GB 1x4GB 1Rx4 1 35V PC3L 10600 CL9 ECC DDR3 1333MHz LP RDIMM 12 6 per processor A2x...

Страница 14: ...SATA hot swap drive bays Twelve 3 5 inch SAS SATA hot swap drive bays Fourteen 3 5 inch SAS SATA hot swap drive bays In addition four and eight bay models support the installation of either an internal optical drive or an internal tape drive The following figure shows some of these configurations Figure 7 Internal drive configurations Standard models ship with four or eight 3 5 inch SATA simple sw...

Страница 15: ... Cage assembly Note Option 00D9051 x3630 M4 ODD Cage assembly comes standard with every four or eight bay standard model listed in Table 2 Option 90Y6370 upgrades any four or eight bay model with an internal tape drive bay for DDS5 or DDS6 tape drives This option includes one USB cable and one power cable The tape drive is ordered separately This option is mutually exclusive with 90Y6370 ODD Cage ...

Страница 16: ...Table 13 PCI riser card options for more details The following table lists drive types and internal drive bay configurations supported by the RAID controllers SAS HDDs include both SAS and NL SAS HDDs and SATA HDDs include both SATA and NL SATA HDDs Table 9 Drive types and internal drive bay configurations supported by the RAID controllers and HBAs RAID controller or HBA Drive type 8x 3 5 in hot s...

Страница 17: ...upports RAID levels 0 1 and 10 Supports RAID levels 5 and 50 with optional M1100 Series RAID 5 upgrades Up to 6 Gbps throughput per port PCIe 2 0 x8 host interface Based on the LSI SAS2008 6 Gbps ROC controller The ServeRAID M5110 SAS SATA Controller has the following specifications Eight internal 6 Gbps SAS SATA ports Two x4 mini SAS internal connectors SFF 8087 Supports connections to SAS SATA d...

Страница 18: ...L SAS 3 5 G2HS SED 14 3 5 NL SAS Hot Swap HDDs 90Y8567 A26M 1TB 7 2K 6Gbps NL SAS 3 5 G2HS HDD 14 90Y8572 A2U0 2TB 7 2K 6Gbps NL SAS 3 5 G2HS HDD 14 90Y8577 A2R2 3TB 7 2K 6Gbps NL SAS 3 5 G2HS HDD 14 49Y6210 A4AF 4TB 7 2K 6Gbps NL SAS 3 5 G2HS HDD 14 00ML213 AS78 6TB 7 2K 6Gbps NL SAS 3 5 G2HS 512e HDD 14 3 5 NL SATA Hot Swap HDDs 81Y9786 A22Y 500GB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 14 81Y9790 A22P ...

Страница 19: ...S 14 00AJ470 A56E S3500 480GB SATA 3 5 MLC HS Enterprise Value SSD 14 00AJ475 A56F S3500 800GB SATA 3 5 MLC HS Enterprise Value SSD 14 3 5 SATA Hot swap Entry SSDs 00FN352 AS0K 240GB SATA 3 5 MLC HS Entry SSD 14 00FN357 AS0L 480GB SATA 3 5 MLC HS Entry SSD 14 00FN362 AS0M 960GB SATA 3 5 MLC HS Entry SSD 14 Part number Feature code Description Maximum supported Internal backup units The server supp...

Страница 20: ...B 8X DVD RW 4 7 GB 8X DVD RAM 4 7 GB 5X UltraSlim Enhanced SATA Multi Burner 46M0902 supports the same media and speeds for reading as DVD ROM 46M0901 This drive also supports the following media and speeds for writing CD R 24X CD RW 24X DVD R 4 7 GB 8X DVD R dual layer 8 5 GB 6X DVD R 4 7 GB 8X DVD R dual layer 8 5 GB 6X DVD RW 4 7 GB 6X DVD RW 4 7 GB 8X DVD RAM 4 7 GB 5X I O expansion options Th...

Страница 21: ...ull height half length Slot 2 PCIe 3 0 x8 x8 wired low profile half length not present if an optional x16 wired slot 1 riser is used Slot 3 PCIe 3 0 x8 x4 wired optional PCIe 3 0 x8 x8 wired dedicated slot for ServeRAID adapter x8 wired slot requires the second processor x4 wired slot does not require the second processor Note The 3 5 Hot Swap Cage Assembly Rear 2 x 3 5 option part number 00D9034 ...

Страница 22: ...ant Integrated PHY for 10 100 1000 Mbps for multispeed full and half duplex auto negotiation IEEE 802 3x and 802 3z compliant flow control support with software controllable Rx thresholds and Tx pause frames Automatic cross over detection function MDI MDI X IEEE 1588 protocol and 802 1AS implementation IEEE802 3az Energy Efficient Ethernet EEE Full wake up support Advanced Power Management APM sup...

Страница 23: ...hernet Quad Port Server Adapter I340 T4 4 00AG500 A56K Intel I350 F1 1xGbE Fiber Adapter 4 00AG510 A56L Intel I350 T2 2xGbE BaseT Adapter 4 00AG520 A56M Intel I350 T4 4xGbE BaseT Adapter 4 Integrated NIC upgrades 90Y9314 A2GT Intel I 350 Embedded Dual Port GbE Activation FoD 1 40 Gb Ethernet FDR InfiniBand 00D9550 A3PN Mellanox ConnectX 3 40GbE FDR IB VPI Adapter 4 10 Gb Ethernet 44T1370 A5GZ Broa...

Страница 24: ...torage HBAs supported by the x3630 M4 server Table 16 Storage adapters Part number Feature code Description Maximum supported Fibre Channel 16 Gb 81Y1662 A2W6 Emulex 16Gb FC Dual port HBA 4 81Y1655 A2W5 Emulex 16Gb FC Single port HBA 4 00Y3337 A3KW QLogic 16Gb FC Single port HBA 4 00Y3341 A3KX QLogic 16Gb FC Dual port HBA 4 Fibre Channel 8 Gb 42D0494 3581 Emulex 8Gb FC Dual port HBA 4 42D0485 3580...

Страница 25: ...egory http lenovopress com servers options ssdadapter GPU adapters The server supports graphics processing units GPUs provided riser card 90Y6381 or FC A1ZB is installed The following table lists the supported GPUs Table 18 GPU adapters Part number Feature code Description Maximum supported None A3WH NVIDIA Quadro K600 1 None A3WJ NVIDIA Quadro K2000 1 This adapter can only be ordered through CTO ...

Страница 26: ...wing table lists the virtualization options Table 20 Virtualization options Part number Feature code Description Maximum supported 41Y8298 A2G0 Blank USB Memory Key for VMware ESXi Downloads 1 41Y8311 A2R3 USB Memory Key for VMware ESXi 5 1 1 41Y8382 A4WZ USB Memory Key for VMware ESXi 5 1 Update 1 1 41Y8385 A584 USB Memory Key for VMware ESXi 5 5 1 Systems management The server contains Integrate...

Страница 27: ...etting and its effect on the Ethernet ports Note The IMM2 network must operate 100 Mbps full duplex The IMM2 network connection does not support Gigabit Ethernet In shared mode the production Ethernet network on that port still operates at Gigabit speeds Table 26 UEFI settings for remote access to the IMM UEFI mode Ethernet Port 1 Ethernet Port 2 Ethernet Port 3 optional Ethernet Port 4 optional I...

Страница 28: ...asic level 1 light path for models with eight drive bays Figure 9 Basic level 1 light path for storage rich models The following figure shows the advanced level 2 light path level Figure 10 Advanced level 2 light path for models with eight drive bays System x3630 M4 E5 2400 28 ...

Страница 29: ...ed Hat Enterprise Linux 6 Server Edition Red Hat Enterprise Linux 6 Server x64 Edition SUSE LINUX Enterprise Server 10 for AMD64 EM64T SUSE LINUX Enterprise Server 10 for x86 SUSE LINUX Enterprise Server 11 for AMD64 EM64T SUSE LINUX Enterprise Server 11 for x86 SUSE LINUX Enterprise Server 11 with Xen for AMD64 EM64T VMware ESX 4 1 VMware ESXi 4 1 VMware vSphere 5 0 ESXi VMware vSphere 5 1 ESXi V...

Страница 30: ... kilovolt amperes kVA approximately Minimum configuration 0 15 kVA Maximum configuration 1 02 kVA Models with 750 W hot swap power supplies 100 127 nominal V AC 50 Hz or 60 Hz 8 9 A 200 240 nominal V AC 50 Hz or 60 Hz 4 5 A Input kilovolt amperes kVA approximately Minimum configuration 0 14 kVA Maximum configuration 0 90 kVA Models with 550 W hot swap power supplies 100 127 nominal V AC 50 Hz or 6...

Страница 31: ...g Monday 9x5 next business day A service technician is scheduled to arrive at the client s location on the business day after remote problem determination is completed Lenovo provides service 8 00 am 5 00 pm in the client s local time zone Monday Friday excluding Lenovo holidays Calls received after 4 00 pm local time require an extra business day for service dispatch Next business day service is ...

Страница 32: ...ssues RTS can reduce problem resolution time decreasing the cost to address technical problems and increasing uptime Offerings are available for Windows Linux IBM Systems Director VMware Microsoft business applications and Lenovo System x storage devices and IBM OEM storage devices Regulatory compliance The server conforms to the following standards FCC Verified to comply with Part 15 of the FCC R...

Страница 33: ...as the following specifications Eight external 6 Gbps SAS SATA ports up to 6 Gbps throughput per port Two external x4 mini SAS connectors SFF 8088 Supports RAID levels 0 1 and 10 Supports RAID levels 5 and 50 with optional M5100 Series RAID 5 upgrades Supports RAID 6 and 60 with the optional M5100 Series RAID 6 Upgrade Supports 512 MB battery backed cache or 512 MB 1 GB or 2 GB flash backed cache ...

Страница 34: ...external expansion enclosures Part number Description Maximum quantity supported per one enclosure 3 5 NL SAS HS HDDs 00NC555 2TB 7 200 rpm 6Gb SAS NL 3 5 HDD 12 00NC557 3TB 7 200 rpm 6Gb SAS NL 3 5 HDD 12 00NC559 4TB 7 200 rpm 6Gb SAS NL 3 5 HDD 12 The following table lists the hard disk drives that are supported by EXP2524 external expansion enclosures Table 29 Drive options for EXP2524 external...

Страница 35: ...l Controller Rack Kit 9x5NBD 64116B1 Lenovo Storage S3200 LFF Chassis FC iSCSI Single Controller Rack Kit 9x5NBD 64116B2 Lenovo Storage S3200 LFF Chassis FC iSCSI Dual Controller Rack Kit 9x5NBD 64113B3 Lenovo Storage S3200 SFF Chassis SAS Single Controller Rack Kit 9x5NBD 64113B4 Lenovo Storage S3200 SFF Chassis SAS Dual Controller Rack Kit 9x5NBD 64116B3 Lenovo Storage S3200 SFF Chassis FC iSCSI...

Страница 36: ...e Drive Model H5S 6171S4R IBM TS2900 Tape Autoloader w LTO4 HH SAS 6171S5R IBM TS2900 Tape Autoloader w LTO5 HH SAS 6171S6R IBM TS2900 Tape Autoloader w LTO6 HH SAS 61732UL IBM TS3100 Tape Library Model L2U 61734UL IBM TS3200 Tape Library Model L4U Fibre Channel backup drives for TS3100 and TS3200 Tape Libraries 00NA101 6173 LTO Ultrium 4 Fibre Channel Drive Sled 00NA103 6173 LTO Ultrium 4 Half Hi...

Страница 37: ...ress com servers options switches Uninterruptible power supply units The following table lists the uninterruptible power supply UPS units that are offered by Lenovo that can be used in x3630 M4 solutions Table 33 Uninterruptible power supply units Part number Description 55941AX RT1 5kVA 2U Rack or Tower UPS 100 125VAC 55941KX RT1 5kVA 2U Rack or Tower UPS 200 240VAC 55942AX RT2 2kVA 2U Rack or To...

Страница 38: ...46M4137 0U 12 C19 12 C13 Switched and Monitored 32A 3 Phase PDU with IEC 309 3P N Gnd cord 46M4134 0U 12 C19 12 C13 Switched and Monitored 50A 3 Phase PDU with CS8365L 3P Gnd cord Ultra Density Enterprise PDUs 9x IEC 320 C13 3x IEC 320 C19 outlets 71762NX Ultra Density Enterprise C19 C13 PDU Module without line cord 71762MX Ultra Density Enterprise C19 C13 PDU Module without line cord 71763NU Ultr...

Страница 39: ...I 32a Line Cord IEC 309 P N G 40K9613 DPI 63a Cord IEC 309 P N G 40K9614 DPI 30a Line Cord NEMA L6 30P 40K9615 DPI 60a Cord IEC 309 2P G 40K9617 DPI Australian NZ 3112 Line Cord 40K9618 DPI Korean 8305 Line Cord Part number Description For more information see the list of Product Guides in the Power Distribution Units category http lenovopress com servers options pdu Rack cabinets The following ta...

Страница 40: ...nce experience for customers like you who want to maximize your purchase power by obtaining the technology you need today protect against technology obsolescence and preserve your capital for other uses We work with businesses non profit organizations governments and educational institutions to finance their entire technology solution We focus on making it easy to do business with us Our highly ex...

Страница 41: ...e http ibm com support entry portal docdisplay lndocid MIGR 5090171 System x3630 M4 Problem Determination and Service Guide http ibm com support entry portal docdisplay lndocid MIGR 5090165 ServerProven hardware compatibility page for the x3630 M4 http www lenovo com us en serverproven xseries 7158 shtml Configuration and Option Guide http www ibm com systems xbc cog xREF System x Reference Sheets...

Страница 42: ...ument are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third par...

Страница 43: ...inkServer ServerProven System x RackSwitch ServeRAID ServerGuide The following terms are trademarks of other companies Intel Pentium and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds in the United States other countries or both Microsoft and Windows are trademarks of Micros...

Отзывы: