Cable storage 

|

 Stage 

3

Cabling a DM7100H system 

to three DM240S shelves

Connect the shelf-to-shelf ports

mini-SAS HD

1

2

A

B

1

2

A

B

1

2

A

B

2

1

3

4

5

2

1

3

4

5

Shelf 1

Shelf 2

Shelf 3

IOMA

IOMB

Controller A

Controller B

0a

0d

0a

0d

1

3

1

1

3

3

1

1

3

1

3

3

Connect Controller B to the drive shelves

Connect Controller A to the drive shelves

Pull-tab

Attention: Be sure to check the illustration arrow for the 

proper cable connector pull-tab orientation.

Note:

 

To unplug a cable, gently pull the tab to release the locking mechanism.

 

Pull-tab

NOTE:

 

Prior to connecting the Nodes to the IOMs in the stack, 

verify that the Tied Controller System ID matches your DM controller 

Serial Number using the label on the top of the expansion shelf.

Refer to the label graphics on the right.

Tied Controller System

连接控制器系统

Stack #:        1

DM MT-M:  7YXX-CTO1WW

DM SN:        XXXXXXXX

Printed in China

(1P) P/N: SP47A30389

Содержание DM7100H

Страница 1: ...er DM7100H chassis 4U for each DM600S shelf or 2U for each DM240S shelf or 2U for each DM120S shelf Additional network cables For connecting your storage system to your network switch and Microsoft Windows client RJ 45 cables Wrench port e0M BMC order dependent Storage Cables mini SAS HD to mini SAS HD cables 100 GbE cables QSFP28 25 GbE cables SFP28 HA interconnect GbE network cables 32 Gb FC SFP...

Страница 2: ...r source yet The system will boot as soon as the power cables are plugged into the power source and power supplies 100 GbE cables cluster network Connect ports to the FC data network switches optional configuration dependent Connect the Wrench port e0M BMC to the management switches Connect the mezzanine cards e0e through e0h to either 16 Gb FC or 25 GbE switches configuration dependent Strap the ca...

Страница 3: ...s Pull tab Attention Be sure to check the illustration arrow for the proper cable connector pull tab orientation Note To unplug a cable gently pull the tab to release the locking mechanism Pull tab NOTE Prior to connecting the Nodes to the IOMs in the stack verify that the Tied Controller System ID matches your DM controller Serial Number using the label on the top of the expansion shelf Refer to ...

Страница 4: ... datacentersupport lenovo com Lenovo Data Center Support Web site Chinese Mainland http support lenovo com cn EsWeb First Edition February 2020 Copyright Lenovo 2020 LIMITED AND RESTRICTED RIGHTS NOTICE If data or software is delivered pursuant to a General Services Administration GSA contract use reproduction or disclosure is subject to restrictions set forth in Contract No GS 35F 05925 LENOVO an...

Отзывы: