background image

Complete system setup and configuration 

|

 Stage 

4

Cable the Data Hosts

Cable the system according to your network topology.

Direct-attach topology

Option

Connect each host adapter directly to the host ports on the controllers.

IP address: 192.168.128.101

IP address: 192.168.128.100

Subnet mask: 255.255.255.0

1. Using an Ethernet cable, connect to controller A port 1 (P1). to the ethernet port on

   your laptop.

1

2. Manually specify the following IP address and subnet mask on the laptop’s  

    Ethernet port that you have physically connected to the storage array:

Fabric topology

Option

Connect each host adapter directly to the switch.
Connect each switch directly to the host ports on the controllers.

1
2

Connect and Configure the Management Connection

3. Use the laptop’s browser to access the storage array’s management  

    software using the following IP address:

After Installing the Hardware

1. Use the ThinkSystem SAN OS software to configure and manage your storage arrays.
2. In the simplest network configuration, connect your controller to a web browser and use 

   ThinkSystem System Manager for managing a single DE-series storage array. 

3. In a more complex environment, use the ThinkSystem SAN Manager for managing multiple 

    storage arrays.

4. In the management software, go to the Hardware tab and select Show back of shelf  

    under Controller Shelf. Highlight controller B, and then select Configure management   

    ports to set the IP addresses for management port 1 on controller B. Do not configure  

    management port 2. This port is reserved for Lenovo technical support. After you  

    have configured controller B’s management port, repeat for controller A.
5. Disconnect your laptop from the storage array and connect an Ethernet cable  

    to management port 1 (labeled P1) on each DE4000H and DE6000H  controller    

    and connect the other end to your network.

DE6000H controller 

0a

0b

P1

P2

EXP1

EXP2

P1

P2

DE4000H controller 

1

Содержание DE4000H

Страница 1: ...yright Lenovo 2020 LIMITED AND RESTRICTED RIGHTS NOTICE If data or software is delivered pursuant to a General Services Administration GSA contract use reproduction or disclosure is subject to restrictions set forth in Contract No GS 35F 05925 LENOVO LENOVO logo and THINKSYSTEM are trademarks of Lenovo Microsoft and Windows are trademarks of the Microsoft group of companies All other trademarks ar...

Страница 2: ... fewer than 60 drives if you have solid state drives SSDs or if your drives have different capacities Maintain a minimum of 20 drives per shelf Install drives in the front four slots in each drawer first for adequate airflow for cooling Distribute any remaining drives across the drawers If possible install an equal number of each type of drive in each drawer to allow for the creation of Drawer Los...

Страница 3: ...helf 1 Cable IOM A of the first drive shelf to IOM A of the second drive shelf 2 Cable IOM B of the first drive shelf to IOM B of the second drive shelf 3 Cable controller B to IOM B of the second drive shelf 4 CAUTION Confirm the drive shelf power switches are off 3 Turn on the two power switches on the controller shelf 4 Check the LEDs and seven segment display on each controller During the boot...

Страница 4: ...ddress After Installing the Hardware 1 Use the ThinkSystem SAN OS software to configure and manage your storage arrays 2 In the simplest network configuration connect your controller to a web browser and use ThinkSystem System Manager for managing a single DE series storage array 3 In a more complex environment use the ThinkSystem SAN Manager for managing multiple storage arrays 4 In the managemen...

Отзывы: