Chapter 7. Resolving installation issues
Use the information in this section to diagnose and resolve problems that you might encounter during the
initial installation and setup of your server.
• “Server does not power on” on page 237
• “The server immediately displays the POST Event Viewer when it is turned on” on page 238
• “Embedded hypervisor is not in the boot list” on page 238
• “Server cannot recognize a drive” on page 238
• “Displayed system memory is less than installed physical memory” on page 239
• “A Lenovo optional device that was just installed does not work.” on page 241
• “Voltage planar fault is displayed in the event log” on page 241
Server does not power on
Complete the following steps until the problem is resolved:
Note:
The power-control button will not function until approximately 5 to 10 seconds after the server has
been connected to power.
1. Make sure that the power-control button is working correctly:
a. Disconnect the server power cords.
b. Reconnect the power cords.
c. (Trained technician only) Reseat the operator information panel cable, and then repeat steps 1a and
1b.
• (Trained technician only) If the server starts, reseat the operator information panel. If the problem
remains, replace the operator information panel.
• If the server does not start, bypass the power-control button by using the force power-on jumper.
If the server starts, reseat the operator information panel. If the problem remains, replace the
operator information panel.
2. Make sure that the reset button is working correctly:
a. Disconnect the server power cords.
b. Reconnect the power cords.
c. (Trained technician only) Reseat the operator information panel cable, and then repeat steps 2a and
2b.
• (Trained technician only) If the server starts, replace the operator information panel.
• If the server does not start, go to step 3.
3. Make sure that both power supplies installed in the server are of the same type. Mixing different power
supplies in the server will cause a system error (the system-error LED on the front panel turns on).
4. Make sure that:
• The power cords are correctly connected to the server and to a working electrical outlet.
• The type of memory that is installed is correct.
• The DIMMs are fully seated.
• The LEDs on the power supply do not indicate a problem.
• The processors are installed in the correct sequence.
5. Reseat the following components:
a. Operator information panel connector
© Copyright Lenovo 2020, 2021
237
Содержание 7X59
Страница 1: ...ThinkSystem SR860 V2 Setup Guide Machine Types 7X59 and 7X60 ...
Страница 8: ...vi ThinkSystem SR860 V2Setup Guide ...
Страница 50: ...42 ThinkSystem SR860 V2Setup Guide ...
Страница 79: ...5 0 1 2 3 1100 mm C0 C1 Slot 10 6 4 5 6 7 1100 mm C0 C1 Slot 12 Chapter 3 Internal cable routing 71 ...
Страница 132: ...124 ThinkSystem SR860 V2Setup Guide ...
Страница 136: ...128 ThinkSystem SR860 V2Setup Guide ...
Страница 154: ...146 ThinkSystem SR860 V2Setup Guide ...
Страница 250: ...242 ThinkSystem SR860 V2Setup Guide ...
Страница 254: ...246 ThinkSystem SR860 V2Setup Guide ...
Страница 258: ...250 ThinkSystem SR860 V2Setup Guide ...
Страница 259: ......
Страница 260: ......