Region
Contact
NA
EMEA
Note:
Make sure that you copy Mark Hof ([email protected]) on all EMEA
inquires
UKIR
Steven Anderson3 ([email protected])
France/Benelux/Scandin. &
Finland
Regis Clermont ([email protected])
Italy/Iberia
Samuel Benedetti ([email protected])
North-West Africa
Angel Carreras Fernandez1 ([email protected])
Russia/EECA
Alexander Totikov ([email protected])
PL, CZ and SK (AR+UN)/ SEE (IN
+UN)/ Greece (IN+UN
Mark Hof ([email protected])
Acting
Middle-East/Pakistan
Alaa Halime ([email protected])
DACH (Shared)/Israel (Andre)/
Baltics (Andre)
Uwe Nunweiler ([email protected])
Andre Reuber ([email protected])
Southern Africa/Eastern Africa/
Egypt and Turkey
Amir Yassien ([email protected])
AP/PRC
Kevin Yuan ([email protected])
IBM to Lenovo server upgrade batch file examples
This topic provides examples of the VPD batch files used to upgrade an IBM System x3850 X6 and x3950 X6
Type 3837 server to a Lenovo System x3850 X6 and x3950 X6 Type 6241 server.
The following sections show sample VPD batch files for Lenovo System x3850 X6 4-socket and Lenovo
System x3950 X6 8-socket systems
Example VPD batch file for a Lenovo System x3850 X6 4-socket system
The Lenovo System x3850 X6 4-socket system requires a single VPD batch file. An example batch file is
shown below:
rem Lenovo server machine type and model requires a total of 7 characters with no double quotes
asu64 set SYSTEM_PROD_DATA.SysInfoProdName 6241F4Y --host 192.168.70.125 --user USERID --password PASSW0RD
rem Lenovo server product indentifier requires double quotes
asu64 set SYSTEM_PROD_DATA.SysInfoProdIdentifierEx "Lenovo System x3850 X6" --override --host 192.168.70.125
--user USERID --password PASSW0RD
rem Lenovo server serial number requires a total of 7 characters with no double quotes
asu64 set SYSTEM_PROD_DATA.SysInfoSerialNum KQ7CFR3 --host 192.168.70.125 --user USERID --password PASSW0RD
rem Lenovo server UUID requires a total of 16 characters entered in hexadecimal with no double quotes
asu64 set SYSTEM_PROD_DATA.SysInfoUUID 5CCEDA3465F436E8ADFA6EAE8B4B77B9 --host 192.168.70.125 --user USERID
--password PASSW0RD
rem Lenovo server component part numbers require double quotes and a total of 12 characters including
insertion of 5 blanks
asu64 set VPD.CompVPD_PartNumber.1 "00D0485
" --host 192.168.70.125 --user USERID --password PASSW0RD
asu64 set VPD.CompVPD_PartNumber.3 "00D0510
" --host 192.168.70.125 --user USERID --password PASSW0RD
asu64 set VPD.CompVPD_PartNumber.4 "78P3448
" --host 192.168.70.125 --user USERID --password PASSW0RD
336
System x3850 X6 and x3950 X6 Installation and Service Guide
Содержание 6241
Страница 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Страница 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Страница 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1989: ......
Страница 1990: ......