Step 3. Remove the storage book from the server (see “Removing the storage book” on page 273).
Step 4. Remove the drive filler panels.
Step 5. Pull the drives out of the front of the storage book slightly to disengage them from the drive
backplane.
Step 6. Disconnect the power cable from the backplane. If a SAS signal cable is attached to the drive
backplane, disconnect it.
Step 7. Lift the retention latch outward on the right side of the backplane cage; then, rotate the backplane
to the left and pull it out of the slots on the cage and remove it from the storage book.
Step 8. If you are instructed to return the drive backplane, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Replacing the 4x2.5-inch hot-swap drive backplanes
Use this information for instructions on how to replace the 4x2.5-inch hot-swap drive backplane assembly.
To install the replacement hot-swap 2.5-inch drive backplanes, complete the following steps:
1. Align the tabs on the side of the drive backplane with the slots on the left side of the backplane cage.
2. Insert the drive backplane tabs into slots on the backplane cage and pull the retention latch back, then
push the drive backplane forward into the retention latch right side of the backplane cage until the
backplane is locked in place.
.
Removing and replacing components
243
Содержание 6241
Страница 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Страница 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Страница 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1989: ......
Страница 1990: ......