9
8. Output signal memory
F21
0
outputs reset after having switched on the power supply
1
same switching status as prior to switching on the power
supply, monostable times, however, being started anew
9. Input signal level
F24
0
npn: active level: Low
1
pnp: active level: High
10. Lock keyboard reset
F26
0
1
if the signal
Keylock is active, the keyboard reset is
not locked,
locked
11. Programming lock for the set value
F27
0
1
if the
Keylock signal is active, the key combination is
+
F1
unlocked,
locked
12. Programming lock for display parameters
F28
0
1
if the
Keylock signal is active, the key combination is
+
F2
not locked,
locked
13. Programming lock for preselection
F29
0
1
2
3
if the
Keylock signal is active, the key(s)
F1
and
F2
are not locked
F1
is locked (preselection P1)
F2
is locked (preselection P2)
F1
and
F2
are locked (both preselections)
14. Standard settings
F30
0
no function
1
all parameters are set to standard (upon pressing the store
key)
Use the cursor key to select the requested option and confirm by pressing
the
key; thus the subsequent parameter will be automatically activated.
To return to the counting mode
−
press the store key
longer than 2 seconds or
−
this is performed automatically approx. 40 seconds after having last
actuated any key (modified parameters will not be saved).